Product Information » 
Introduction of Products by Theme ⁄ Industry » Pneumatic Equipment for Food Industry » Industry » Confectionery, Noodle, Bread Production, etc. » Caser robot » Reduced-wiring
                    
                
                
                
                
                
                                    Pneumatic Equipment for Food Industry ⁄ Industry
Caser robot Reduced-wiring
Serial Transmission System EX260
Directional Control Valves » Reduced-wiring Fieldbus System (Serial Transmission System)Industrial Device Communication Equipment/Wireless System » Industrial Device Communication Equipment: PROFINET Compatible Products
Industrial Device Communication Equipment/Wireless System » Industrial Device Communication Equipment: EtherNet/IP Compatible Products
Industrial Device Communication Equipment/Wireless System » Industrial Device Communication Equipment: EtherCAT Compatible Products
Industrial Device Communication Equipment/Wireless System » Industrial Device Communication Equipment: ETHERNET POWERLINK Compatible Products
Industrial Device Communication Equipment/Wireless System » Industrial Device Communication Equipment: PROFIsafe Compatible Products
Industrial Device Communication Equipment/Wireless System » Industrial Device Communication Equipment: IO-Link Compatible Products
Industrial Device Communication Equipment/Wireless System » Industrial Device Communication Equipment: PROFIBUS Compatible Products
Industrial Device Communication Equipment/Wireless System » Industrial Device Communication Equipment: DeviceNet Compatible Products
Industrial Device Communication Equipment/Wireless System » Industrial Device Communication Equipment: CC-Link Compatible Products
IO-Link Devices » SI Unit
- 
                
    For Output
 
∗The applicable protocols differ depending on the series.
For details, refer to the catalog of each series.
・IP67
・RJ45 communication connectors (X205)
▶IO-Link Master
                    Safety Instructions 
                    3/4/5 Port Solenoid Valves/Precautions 
                    Fieldbus System Precautions 
                    Industrial IoT Cybersecurity 
                    Glossary of Fieldbus Terms 
                    Series Variations/Applicable Valve Series 
                    Safety over Fieldbus with PROFIsafe 
                    Green Procurement (RoHS) 
                    IO-Link Master 
                
        
    | Series | Enclosure | Communication protocol∗ | Applicable valve | 
|---|---|---|---|
| EX260 | IP67 | DeviceNet™ PROFIBUS DP CC-Link EtherCAT PROFINET EtherNet/IP™ Ethernet POWERLINK IO-Link (Only available for SY, JSY, VQC communication connectors) PROFIsafe (Only available for SY, JSY, VQC communication connectors)  | 
                                    SY3000,5000,7000 (Plug-in) JSY1000,3000,5000 (Plug-in) VQC1000,2000,4000,5000 SV1000,2000,3000 S0700(IP40)  | 
                            
Serial Transmission System EX250
Directional Control Valves » Reduced-wiring Fieldbus System (Serial Transmission System)Industrial Device Communication Equipment/Wireless System » Industrial Device Communication Equipment: EtherNet/IP Compatible Products
Industrial Device Communication Equipment/Wireless System » Industrial Device Communication Equipment: PROFIBUS Compatible Products
Industrial Device Communication Equipment/Wireless System » Industrial Device Communication Equipment: DeviceNet Compatible Products
Industrial Device Communication Equipment/Wireless System » Industrial Device Communication Equipment: AS-interface Compatible Products
Industrial Device Communication Equipment/Wireless System » Industrial Device Communication Equipment: CANopen Compatible Products
                                - 
                
    For Input/Output
 
∗The applicable protocols differ depending on the series.
For details, refer to the catalog of each series.
                    Safety Instructions 
                    3/4/5 Port Solenoid Valves/Precautions 
                    Fieldbus System Precautions 
                    Industrial IoT Cybersecurity 
                    Glossary of Fieldbus Terms 
                    Series Variations/Applicable Valve Series 
                    Green Procurement (RoHS) 
                
        
    | Series | Enclosure | Communication protocol∗ | Applicable valve | 
|---|---|---|---|
| EX250 | IP67 | DeviceNet™ PROFIBUS DP CC-Link AS-Interface CANopen EtherNet/IP™  | 
                                    JSY1000, 3000, 5000 (Plug-in) SY3000,5000,7000 (Plug-in) VQC1000,2000,4000,5000 SV1000,2000,3000 S0700(IP40)  | 
                            
M8/M12 Connector PCA/EX9/EX500
Directional Control Valves » Reduced-wiring Fieldbus System (Serial Transmission System)
                                - 
                
    ・Communication cable/connector: CC-Link, DeviceNet™, PROFIBUS DP, 
 
EtherNet/IP™, PROFINET, EtherCAT🄬, Ethernet POWERLINK
・Compliant with IEC61076-2-101 and IEC60947-5-2 Standards
・IP67 (IEC60529)
・Field-wireable connectors: No exclusive tools required, Reduction in wiring time
・SPEEDCON: Just insert the connector and make a 180° rotation.
                    Safety Instructions 
                    3/4/5 Port Solenoid Valves/Precautions 
                    Fieldbus System Precautions 
                    Industrial IoT Cybersecurity 
                    Glossary of Fieldbus Terms 
                    Series Variations/Applicable Valve Series 
                    Green Procurement (RoHS) 
                
        
    | Series | 
|---|
| PCA | 
| EX9 | 
| EX500 | 
















                        
                        
                        
                        
                        
                        
                        
                        
                        
                        
                        
                        
                        
                        
                        
                        
                        
                        
                        
                        
                        
                        
                        
                        
                        
                        
                        
                        
                            
                