Product Information »
Introduction of Products by Theme ⁄ Industry » Pneumatic Equipment for Food Industry » Industry » Confectionery, Noodle, Bread Production, etc. » Stirring/Mixing » Electric ⁄ Positioning » Controller
Pneumatic Equipment for Food Industry ⁄ Industry
Stirring/Mixing Electric/Positioning Controller
Controller/Step Data Input Type LECA6
Electric Actuators/Cylinders » Controllers/Drivers-
・The controller is already set with the data of the actuator.
(The actuator and controller are provided as a set.)
・Easy operation and simple setting: Easy mode, Detail setting: Normal mode
・Teaching box, controller setting software
Safety Instructions
Electric Actuators/Precautions
Features
Series Variations
Simplified Selection Flow Chart
Wiring Method
Green Procurement (RoHS)
CE/UL-compliance List
Type | Series | Compatible motor |
Power supply voltage |
Parallel I/O Input |
Parallel I/O Output |
Number of step data |
---|---|---|---|---|---|---|
Step data input type |
LECA6 | Servo motor (24 VDC) |
24 VDC ±10% |
11 (Photo-coupler isolation) |
13 (Photo-coupler isolation) |
64 points |
Multi-Axis Step Motor Controller JXC73/83/92/93
Electric Actuators/Cylinders » Controllers/DriversIndustrial Device Communication Equipment/Wireless System » Industrial Device Communication Equipment: EtherNet/IP Compatible Products
-
・Speed tuning control
・Linear/circular interpolation
・Positioning/pushing operation
・Absolute/relative position coordinate instructions
・Step data input (Max. 2048 points)
・Space saving, reduced wiring
Safety Instructions
Electric Actuators/Precautions
Features
Series Variations
Simplified Selection Flow Chart
Green Procurement (RoHS)
CE/UL-compliance List
Type | Series | I/O type | Compatible motor |
Power supply voltage |
Number of axes |
---|---|---|---|---|---|
Step data input type |
JXC73 | NPN | Step motor (Servo/24 VDC) |
24 VDC ±10% |
Max. 4 axes |
Step data input type |
JXC83 | PNP | Step motor (Servo/24 VDC) |
24 VDC ±10% |
Max. 4 axes |
Step data input type |
JXC92 | EtherNet/IP™ | Step motor (Servo/24 VDC) |
24 VDC ±10% |
Max. 3 axes |
Step data input type |
JXC93 | EtherNet/IP™ | Step motor (Servo/24 VDC) |
24 VDC ±10% |
Max. 4 axes |
Programless Controller LECP1
Electric Actuators/Cylinders » Controllers/Drivers-
・No programming required
Capable of setting up an electric actuator operation without using a PC or teaching box
・Speed/acceleration 16-level adjustment
・Compatible with actuators with locks
・3-level pushing force settings
Safety Instructions
Electric Actuators/Precautions
Features
Series Variations
Simplified Selection Flow Chart
Wiring Method
Green Procurement (RoHS)
Type | Series | Compatible motor |
Power supply voltage |
Parallel I/O Input |
Parallel I/O Output |
Number of step data |
---|---|---|---|---|---|---|
Programless type |
LECP1 | Step motor (Servo/24 VDC) |
24 VDC ±10% |
6 (Photo-coupler isolation) |
6 (Photo-coupler isolation) |
14 points |
Programless Controller (With Stroke Study) LECP2
Electric Actuators/Cylinders » Controllers/Drivers-
・End to end operation similar to an air cylinder
・Positioning of 2 stroke end points + 12 intermediate points
Safety Instructions
Electric Actuators/Precautions
Features
Series Variations
Simplified Selection Flow Chart
Wiring Method
Green Procurement (RoHS)
CE/UL-compliance List
Type | Series | Compatible motor |
Power supply voltage |
Parallel I/O Input |
Parallel I/O Output |
Number of step data |
---|---|---|---|---|---|---|
Programless type (With stroke study) |
LECP2 | Step motor (Servo/24 VDC) |
24 VDC ±10% |
6 (Photo-coupler isolation) |
6 (Photo-coupler isolation) |
2 stroke end points, 12 intermediate points |
Step Motor Driver (Pulse Input Type) LECPA
Electric Actuators/Cylinders » Controllers/Drivers-
・A driver that uses pulse signals to allow positioning at any position
The actuator can be controlled from the customers' positioning unit.
・Return-to-origin command signal
・With force limit function (Pushing force/Gripping force operations are available.)
Safety Instructions
Electric Actuators/Precautions
Features
Series Variations
Simplified Selection Flow Chart
Wiring Method
Green Procurement (RoHS)
Type | Series | Compatible motor |
Power supply voltage |
Parallel I/O Input |
Parallel I/O Output |
Number of step data |
---|---|---|---|---|---|---|
Pulse input type |
LECPA | Step motor (Servo/24 VDC) |
24 VDC ±10% |
5 (Photo-coupler isolation) |
9 (Photo-coupler isolation) |
― |
Step Motor Controller JXCE1/91/P1/D1/L□/M1
Electric Actuators/Cylinders » Controllers/DriversIndustrial Device Communication Equipment/Wireless System » Industrial Device Communication Equipment: PROFINET Compatible Products
Industrial Device Communication Equipment/Wireless System » Industrial Device Communication Equipment: EtherNet/IP Compatible Products
Industrial Device Communication Equipment/Wireless System » Industrial Device Communication Equipment: EtherCAT Compatible Products
Industrial Device Communication Equipment/Wireless System » Industrial Device Communication Equipment: DeviceNet Compatible Products
Industrial Device Communication Equipment/Wireless System » Industrial Device Communication Equipment: CC-Link Compatible Products
-
・EtherCAT, EtherNet/IP™, PROFINET, DeviceNet®,
IO-Link, and CC-Link compatible
・Two types of operation command:
Step no. defined operation, Numerical data defined operation
・Transition wiring of communication cables
・Numerical monitoring available
・IO-Link communication can be performed.
・Controller with STO sub-function/JXC□F
Safety Instructions
Electric Actuators/Precautions
Features
Series Variations
Simplified Selection Flow Chart
Green Procurement (RoHS)
CE/UL-compliance List
Series | Compatible motor |
Power supply voltage |
Fieldbus |
---|---|---|---|
JXCE1 (Standard) JXCEF (With subfunction) |
Step motor (Servo/24 VDC) |
24 VDC ±10% |
EtherCAT™ |
JXC91 (Standard) JXC9F (With subfunction) |
Step motor (Servo/24 VDC) |
24 VDC ±10% |
EtherNet/IP™ |
JXCP1 (Standard) JXCPF (With subfunction) |
Step motor (Servo/24 VDC) |
24 VDC ±10% |
PROFINET |
JXCD1 (Standard) | Step motor (Servo/24 VDC) |
24 VDC ±10% |
DeviceNet™ |
JXCL1 (Standard) JXCLF (With subfunction) |
Step motor (Servo/24 VDC) |
24 VDC ±10% |
IO-Link |
JXCM1 (Standard) | Step motor (Servo/24 VDC) |
24 VDC ±10% |
CC-Link |
Fieldbus-compatible Gateway (GW) Unit LEC-G
Electric Actuators/Cylinders » Controllers/DriversIndustrial Device Communication Equipment/Wireless System » Industrial Device Communication Equipment: EtherNet/IP Compatible Products
Industrial Device Communication Equipment/Wireless System » Industrial Device Communication Equipment: PROFIBUS Compatible Products
Industrial Device Communication Equipment/Wireless System » Industrial Device Communication Equipment: DeviceNet Compatible Products
Industrial Device Communication Equipment/Wireless System » Industrial Device Communication Equipment: CC-Link Compatible Products
-
・The LE□ series electric actuators are applicable to Fieldbus protocols.
・Conversion unit for Fieldbus network and LEC serial communication
・2 methods of operation:
Step data input, numerical data input
・Position, speed, and other values can be checked on the PLC.
Safety Instructions
Electric Actuators/Precautions
Features
Series Variations
Simplified Selection Flow Chart
Wiring Method
Green Procurement (RoHS)
CE/UL-compliance List
Series | Applicable fieldbus | Power supply voltage | Applicable controllers |
---|---|---|---|
LEC-G | CC-Link DeviceNet™ PROFIBUS DP EtherNet/IP™ |
24 VDC ±10% |
LECA6 series |
AC Servo Motor Driver LECS
Electric Actuators/Cylinders » Controllers/DriversIndustrial Device Communication Equipment/Wireless System » Industrial Device Communication Equipment: PROFINET Compatible Products
Industrial Device Communication Equipment/Wireless System » Industrial Device Communication Equipment: SSCNET III Compatible Products
Industrial Device Communication Equipment/Wireless System » Industrial Device Communication Equipment: CC-Link Compatible Products
-
・Pulse input type motor driver
・Compatible motor capacity: 100 W, 200 W, 400 W
・Compatible encoders:
Incremental type
Absolute type
・Servo adjustment using auto gain tuning
・With display setting function
・Positioning by up to 255 point tables
Safety Instructions
Electric Actuators/Precautions
Features
Series Variations
Simplified Selection Flow Chart
Wiring Method
Green Procurement (RoHS)
CE/UL-compliance List
Type | Model | Compatible motor |
Power supply voltage |
Parallel input/output Input |
Parallel input/output Output |
---|---|---|---|---|---|
Pulse input type (For incremental encoder) |
LECSA | AC servo motor (100/200/400 W) |
100 to 120 VAC (50/60 Hz) 200 to 230 VAC (50/60 Hz) |
6 | 4 |
Pulse input type (For absolute encoder) |
LECSB | AC servo motor (100/200/400 W) |
100 to 120 VAC (50/60 Hz) 200 to 230 VAC (50/60 Hz) |
10 | 6 |
CC-Link direct input type (For absolute encoder) |
LECSC | AC servo motor (100/200/400 W) |
100 to 120 VAC (50/60 Hz) 200 to 230 VAC (50/60 Hz) |
― | ― |
SSCNETⅢ type (For absolute encoder) |
LECSS | AC servo motor (100/200/400 W) |
100 to 120 VAC (50/60 Hz) 200 to 230 VAC (50/60 Hz) |
― | ― |
Pulse input type/ Positioning type (For absolute encoder) |
LECSB-T | AC servo motor (100/200/400 W) |
200 to 240 VAC (50/60 Hz) |
10 | 6 |
CC-Link direct input type (For absolute encoder) |
LECSC-T | AC servo motor (100/200/400 W) |
200 to 230 VAC (50/60 Hz) |
― | ― |
Network card type/H type (For absolute encoder) |
LECSN-T | AC servo motor (100/200/400 W) |
200 to 240 VAC (50/60 Hz) |
― | ― |
SSCNETⅢ type/H type (For absolute encoder) |
LECSS-T | AC servo motor (100/200/400 W) |
200 to 240 VAC (50/60 Hz) |
― | ― |
AC Servo Motor Driver (MECHATROLINK Compatible) LECYM/LECYU
Electric Actuators/Cylinders » Controllers/DriversIndustrial Device Communication Equipment/Wireless System » Industrial Device Communication Equipment: MECHATROLINK-Ⅲ Compatible Products
Industrial Device Communication Equipment/Wireless System » Industrial Device Communication Equipment: MECHATROLINK-Ⅱ Compatible Products
-
・Position control, speed control, and torque control can be used.
・Control encoder: Absolute 20-bit encoder
(Resolution: 1048576 p/rev)
・Applicable Fieldbus protocol: MECHATROLINK-Ⅰ, MECHATROLINK-Ⅲ
*Click here for the setup software
Safety Instructions
Electric Actuators/Precautions
Features
Series Variations
Simplified Selection Flow Chart
Green Procurement (RoHS)
CE/UL-compliance List
Type | Series | Compatible motor |
Power supply voltage |
Parallel I/O Input |
Parallel I/O Output |
---|---|---|---|---|---|
MECHATROLINK-Ⅱ type (For absolute encoder) |
LECYM | AC servo motor (100/200/400 W) |
200 to 230 VAC (50/60 Hz) |
7 (Number of optional allocations) |
1 (Number of fixed allocations) 3 (Number of optional allocations) |
MECHATROLINK-Ⅲ type (For absolute encoder) |
LECYU | AC servo motor (100/200/400 W) |
200 to 230 VAC (50/60 Hz) |
7 (Number of optional allocations) |
1 (Number of fixed allocations) 3 (Number of optional allocations) |