Product Information »
Introduction of Products by Theme/Industry »
Film Manufacturing Process Equipment »
7. Drying ⁄ UV Irradiation
|7. Drying ⁄ UV Irradiation
After drying and fixing the coating material to the film, UV irradiation is used to harden the surface.
5 Port Solenoid Valve 10-SY
Clean Series/Low-Particle Generation » Directional Control ValvesClean Series
Safety Instructions
Features/Basic Specifications/Clean Series Precautions
3/4/5 Port Solenoid Valves/Precautions
Green Procurement (RoHS)
Series | Sonic conductance: C | Cylinder size | Power consumptio (W) |
---|---|---|---|
10-SY3000 | 1.1dm3(s・bar) | φ40 | 0.35 |
10-SY5000 | 2.8dm3(s・bar) | φ63 | 0.35 |
10-SY7000 | 4.5dm3(s・bar) | φ80 | 0.35 |
10-SY9000 | 10dm3(s・bar) | φ100 | 0.35 |
5 Port Solenoid Valve 10-SV
Clean Series/Low-Particle Generation » Directional Control ValvesClean Series
Safety Instructions
Features/Basic Specifications/Clean Series Precautions
3/4/5 Port Solenoid Valves/Precautions
Green Procurement (RoHS)
Series | Sonic conductance: C | Cylinder size | Power consumption (W) |
---|---|---|---|
10-SV1000 | 1.1dm3(s・bar) | φ40 | 0.6 |
10-SV2000 | 2.8dm3(s・bar) | φ63 | 0.6 |
10-SV3000 | 4.5dm3(s・bar) | φ80 | 0.6 |
10-SV4000 | 10dm3(s・bar) | φ100 | 0.6 |
4/5 Port Solenoid Valve 10-SYJ
Clean Series/Low-Particle Generation » Directional Control ValvesClean Series
Safety Instructions
Features/Basic Specifications/Clean Series Precautions
3/4/5 Port Solenoid Valves/Precautions
Green Procurement (RoHS)
Series | Sonic conductance: C | Cylinder size | Power consumption (W) |
---|---|---|---|
10-SYJ3000 | 0.46dm3(s・bar) | φ25 | 0.35 |
10-SYJ5000 | 0.83dm3(s・bar) | φ40 | 0.35 |
10-SYJ7000 | 2.9dm3(s・bar) | φ50 | 0.35 |
5 Port Solenoid Valve 10-SZ
Clean Series/Low-Particle Generation » Directional Control ValvesClean Series
Safety Instructions
Features/Basic Specifications/Clean Series Precautions
3/4/5 Port Solenoid Valves/Precautions
Green Procurement (RoHS)
Series | Sonic conductance: C | Cylinder size | Power consumption (W) |
---|---|---|---|
10-SZ3000 | 0.77dm3(s・bar) | φ32 | 0.6 |
5 Port Solenoid Valve 10-S0700
Clean Series/Low-Particle Generation » Directional Control ValvesClean Series
Safety Instructions
Features/Basic Specifications/Clean Series Precautions
3/4/5 Port Solenoid Valves/Precautions
Green Procurement (RoHS)
Series | Flow rate characteristics 1→4/2(P→A/B) C[dm3/(s・bar)] |
Flow rate characteristics 1→4/2(P→A/B) b |
Flow rate characteristics 1→4/2(P→A/B) Cv |
Cylinder size | Power consumption (W) |
---|---|---|---|---|---|
10-S0700 | 0.39 | 0.39 | 0.11 | φ25 | 0.35 |
5 Port Solenoid Valve 10-VQ
Clean Series/Low-Particle Generation » Directional Control ValvesClean Series
Safety Instructions
Features/Basic Specifications/Clean Series Precautions
3/4/5 Port Solenoid Valves/Precautions
Green Procurement (RoHS)
Series | Flow rate characteristics 2/4→3/5 (A/B→R1/R2) C [dm3/(s・bar)] |
Flow rate characteristics 2/4→3/5 (A/B→R1/R2) b |
Flow rate characteristics 2/4→3/5 (A/B→R1/R2) Cv |
Cylinder size | Power consumption (W) |
---|---|---|---|---|---|
10-VQ1000 | 1.0 | 0.30 | 0.25 | φ40 | 0.4 (Basic) |
10-VQ2000 | 3.2 | 0.30 | 0.80 | φ63 | 0.4 (Basic) |
5 Port Solenoid Valve 10-SQ
Clean Series/Low-Particle Generation » Directional Control ValvesClean Series
Safety Instructions
Features/Basic Specifications/Clean Series Precautions
3/4/5 Port Solenoid Valves/Precautions
Green Procurement (RoHS)
Series | Sonic conductance: C | Cylinder size | Power consumption (W) |
---|---|---|---|
10-SQ1000 | 0.83dm3(s・bar) | φ32 | 1.0 |
10-SQ2000 | 2.9dm3(s・bar) | φ63 | 1.0 |
4 Port Solenoid Valve / Direct Operated Poppet Type 10-VQD
Clean Series/Low-Particle Generation » Directional Control ValvesClean Series
Safety Instructions
Features/Basic Specifications/Clean Series Precautions
3/4/5 Port Solenoid Valves/Precautions
Green Procurement (RoHS)
Series | Sonic conductance: C | Cylinder size | Power consumption (W) |
---|---|---|---|
10-VQD1000 | 0.19dm3(s・bar) | φ25 | 2.0 |
3 Port Solenoid Valve 10-V100
Clean Series/Low-Particle Generation » Directional Control ValvesClean Series
*With power saving circuit
Safety Instructions
Features/Basic Specifications/Clean Series Precautions
3/4/5 Port Solenoid Valves/Precautions
Green Procurement (RoHS)
Model | Type | Sonic conductance: C | Power consumption (W) |
---|---|---|---|
10-V100 | Standard type | 0.037dm3(s・bar) | 0.35*(0.1) |
10-V100 | Large flow type | 0.076dm3(s・bar) | 1.0 |
3 Port Solenoid Valve 10-SYJ
Clean Series/Low-Particle Generation » Directional Control ValvesClean Series
Safety Instructions
Features/Basic Specifications/Clean Series Precautions
3/4/5 Port Solenoid Valves/Precautions
Green Procurement (RoHS)
Series | Sonic conductance: C | Power consumption (W) |
---|---|---|
10-SYJ300 | 0.36dm3(s・bar) | 0.35 |
10-SYJ500 | 1.2dm3(s・bar) | 0.35 |
10-SYJ700 | 3.0dm3(s・bar) | 0.35 |
3 Port Solenoid Valve 10-SY
Clean Series/Low-Particle Generation » Directional Control ValvesClean Series
★The value indicates the effective area (S).
Safety Instructions
Features/Basic Specifications/Clean Series Precautions
3/4/5 Port Solenoid Valves/Precautions
Green Procurement (RoHS)
Series | Type | Sonic conductance: C | Power consumption (W) |
---|---|---|---|
10-SY100 | Standard type | *0.14mm2 | 0.5 |
10-SY100 | Large flow type | *0.22mm2 | 0.5 |
3 Port Solenoid Valve 10-S070
Clean Series/Low-Particle Generation » Directional Control ValvesClean Series
Safety Instructions
Features/Basic Specifications/Clean Series Precautions
3/4/5 Port Solenoid Valves/Precautions
Green Procurement (RoHS)
Series | Flow rate characteristics C[dm3/(s·bar)] |
Flow rate characteristics b |
Flow rate characteristics Cv |
Power consumption (W) |
Max. operating pressure: MPa |
---|---|---|---|---|---|
10-S070 | 0.042 | 0.27 | 0.011 | 0.5 | 0.5 |
10-S070 | 0.060 | 0.28 | 0.016 | 0.5 | 0.3 |
10-S070 | 0.042 | 0.27 | 0.011 | 0.35 | 0.3 |
10-S070 | 0.060 | 0.28 | 0.016 | 0.35 | 0.1 |
10-S070 | 0.021 | 0.27 | 0.006 | 0.1 (With power saving circuit) |
0.3 |
10-S070 | 0.042 | 0.28 | 0.011 | 0.1 (With power saving circuit) |
0.1 |