WEB Catalog

Product Information »  WEB Catalog  »  Air Cylinders  »  Stroke Reading Cylinders

Stroke Reading Cylinders

Actuator Position Sensor D-MP□

    ・Actuator stroke position is output with an analog signal.
    ・Repeatability: 0.1 mm
    ・Analog output
    ・4 measurement ranges
    ・Switch output
    ・IO-Link compatible
Series Measuring range
D-MP025 25 mm±1 mm
D-MP050 50 mm±1 mm
D-MP100 100 mm±1 mm
D-MP200 200 mm±1 mm

Features

The actuator stroke position is output with an analog signal.

Analog output function

Operation display

  • Direct mounting is possible.

    Can be mounted directly into the auto switch mounting groove on the cylinder

  • Lead wire connection

4 switch modes can be selected for the switch output.

Application examples

IO-Link compatible

Visualization of operation/equipment status/Remote monitoring and control by communication

Go Top