Pilot Operated 3 Port Solenoid Valves
3-Port Solenoid Valve/Pilot Operated Poppet Type VP300/500/700
-
・Built-in full-wave rectifier (AC)
・Longer life expectancy: 50 million cycles or more
・Built-in strainer in the pilot valve
・The external pilot type can be used for vacuum applications.
・Manifold type no.: VV3P3, VV3P5, VV3P7
Series | Flow rate characteristics 2→3(A→P) C[dm3/(s・bar)] |
Flow rate characteristics 2→3(A→P) b |
Flow rate characteristics 2→3(A→P) Cv |
Power consumption (W) |
For use in vacuum applications |
---|---|---|---|---|---|
VP300 | 4.2 | 0.23 | 1.0 | 1.55(Standard) 0.55(With power saving circuit) 0.4(Low wattage specification) |
-100 kPa |
VP500 | 8.9 | 0.20 | 2.1 | 1.55(Standard) 0.55(With power saving circuit) 0.4(Low wattage specification) |
-100 kPa |
VP700 | 15.3 | 0.22 | 3.7 | 1.55(Standard) 0.55(With power saving circuit) |
-100 kPa |
Features
Low wattage specification
Power consumption is reduced
0.55 W [With power saving circuit]
1.55 W [Standard]
* Conventional model: 2.0 W With DC light
Power consumption is reduced by power saving circuit.
Power consumption is decreased by approx. 1/3 by reducing the wattage required to hold the valve in an energized state.
(Effective energizing time is over 40 ms at 24 VDC.)
Refer to electrical power waveform as shown below.
Built-in full-wave rectifier (AC)
Noise reduction
Noise is considerably reduced by changing it to DC mode with a full-wave rectifier.
Reduced apparent power
Conventional 5.6 VA → 1.55 VA [Standard]
Longer life expectancy: 50 million cycles or more
(Conventional: 20 million cycles)
* Based on SMC test conditions.
Built-in strainer in the pilot valve
Unexpected troubles due to foreign matter can be prevented.
Note) Be sure to mount an air filter on the inlet side.