Product Information »
WEB Catalog
»
Directional Control Valves
»
Pilot Operated 4/5 Port Solenoid Valves
Pilot Operated 4/5 Port Solenoid Valves
5-Port Solenoid Valve VF1000/3000/5000
-
・Built-in full-wave rectifier (AC)
・Built-in strainer in the pilot valve
・Manifold type no.: VV5F1, VV5F3, VV5F5
Safety Instructions
3/4/5 Port Solenoid Valves/Precautions
Selection/Technical Data
Green Procurement (RoHS)
Series | Flow rate characteristics 4/2→5/3 (A/B→EA/EB) C[dm3/(s・bar)] |
Flow rate characteristics 4/2→5/3 (A/B→EA/EB) b |
Flow rate characteristics 4/2→5/3 (A/B→EA/EB) Cv |
Applicable cylinder size |
Power consumption (W) |
---|---|---|---|---|---|
VF1000 | 0.53 | 0.28 | 0.13 | φ40 | 1.55(Standard) 0.55(With power saving circuit) 0.4 (Low wattage specification) |
VF3000 | 3.1 | 0.32 | 0.75 | φ80 | 1.55(Standard) 0.55(With power saving circuit) 0.4 (Low wattage specification) |
VF5000 | 10.0 | 0.49 | 2.9 | φ125 | 1.55(Standard) 0.55(With power saving circuit) |
Features
Low wattage specification added
Power consumption
0.35 W (Without light)
0.4 W (With light)
Reduced power consumption
0.55 w [With power saving circuit]
1.55 w [Standard]
(Conventional: 2.0 W)
※With DC light
Power consumption is reduced by power saving circuit.
Power consumption is decreased by approx. 1/3 by reducing the wattage required to hold the valve in an energized state. (Effective energizing time is over 40 ms at 24 VDC.) Refer to electrical power waveform as shown below.
Built-in full-wave rectifier (AC)
Noise reduction
Noise is considerably reduced by changing it to DC mode with a full-wave rectifier.
Reduced apparent power
Conventional: 5.6 VA → 1.55 VA