WEB Catalog

Product Information »  WEB Catalog  »  Fluoropolymer Equipment/PVC Equipment  »  High Purity Chemical Liquid Valves

High Purity Chemical Liquid Valves

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

High Purity Chemical Liquid Valve/Air Operated, Integrated Fitting Type LVC

    ・Body material: New PFA
    ・N.C./N.O./Double acting all feature the same configuration.
    ・Compatible with fluid temperatures of 100℃
    ・Manifold type no.: LLC2, LLC3, LLC4, LLC5
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
Series Type Valve type Applicable tubing O.D. Orifice diameter (mmø)
LVC Air Operated
Integrated fitting
N.C./N.O./
Double acting
Metric: 3 to 25
Inch: 1/8 to 1
4 to 22

High Purity Chemical Liquid Valve/Air Operated, Threaded Type LVA

    ・Body materials: New PFA/Stainless steel/PPS
    ・Diaphragm materials: PTFE, EPR, or NBR can be selected.
    ・Organic solvents compatible
     Body: Stainless steel, Actuator section: ADC, Buffer: Choose from FKM/EPDM
    ・Manifold type no.: LLA2,LLA3,LLA4,LLA5
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
Series Type Valve type Port size
Applicable tubing O.D.
Orifice diameter
(mmø)
LVA Air operated
Threaded type
N.C./N.O./
Double acting
1/8 to 1 2 to 22
LVA Air operated
Organic solvents
compatible
N.C./N.O./
Double acting
Metric: 6 to 19
Inch: 1/4 to 1
4 to 22

High Purity Chemical Liquid Valve/Manually Operated (Integrated Fitting Type/Threaded Type) LVH

    ・Body materials: New PFA/Stainless steel/PPS
    ・Compatible with locking and non-locking types
    ・Organic solvents compatible
     Body: Stainless steel, Actuator section: ADC, Buffer: Choose from FKM/EPDM
    ・Manifold type no.: LLH2,LLH3,LLH4
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
Series Type Valve type Port size
Applicable tubing O.D.
Orifice diameter
(mmø)
LVH Manually operated
(Integrated fitting/Threaded type)
N.C. Threaded type: 1/8 to 1/2
Integrated fitting: Metric: ø3 to ø12
Inch: 1/8 to 1/2
4 to 12
LVH Manually operated
Organic solvents
compatible
N.C. Metric: 6 to 19
Inch: 1/4 to 1
4 to 22

Compact Type High Purity Air Operated Chemical Liquid Valve LVD

    ・Space saving, compact model is available.
     Dimension across inlet/outlet ports: Reduced by up to 29%
    ・Body material: New PFA
    ・Diaphragm material: PTFE
    ・Actuator materials: PPS, PVDF (LVD-F/FN)

    Note) Tubing O.D. for the tube extension type
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
Series Type Valve type Applicable tubing O.D.
Note)
Metric size
Applicable tubing O.D.
Note)
Inch size
Orifice diameter
(mmø)
LVD Integrated fittings N.C./N.O./
Double acting
3 to 19 1/8 to 3/4 2 to 16
LVD Tube extensions N.C./N.O./
Double acting
6 to 19 1/4 to 3/4 4 to 16
LVD-F/FN LQ1 Integrated fittings N.C./N.O./
Double acting
3 to 25 1/8 to 1 4 to 22
LVD-F/FN LQ3 Integrated fittings N.C./N.O./
Double acting
6 to 25 1/4 to 1 4 to 22
LVD-F/FN Tube extensions N.C./N.O./
Double acting
6 to 25 1/4 to 1 4 to 22

High Purity Chemical Liquid Valve/Air Operated, Non-Metallic Exterior LVQ

    ・Screwless construction, Non-metallic construction doesn't use metal screws to secure the body of the actuator
    ・Body material: New PFA
    ・Diaphragm material: PTFE
    ・Actuator material: PVDF

    Note) Tubing size
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
  • High Purity Chemical Liquid Valve/Air Operated, Non-Metallic Exterior LVQ
    Manual
    Series Type View search result
    LVQ Integrated fitting View search result
    LVQ Space saving type View search result
    LVQ Tube extension View search result
Series Type Valve type Applicable tubing O.D.
Metric size
Applicable tubing O.D.
Inch size
Orifice diameter
(mmø)
LVQ Integrated fitting N.C./N.O./
Double acting
3 to 25 1/8 to 1 4 to 22
LVQ Space saving type N.C./N.O./
Double acting
Fitting size:
2 to 6
Fitting size:
2 to 6
4 to 22
LVQ Tube extension N.C./N.O./
Double acting
6 to 25 Note) 1/4 to 1 Note) 4 to 22

Go Top