WEB Catalog

Product Information »  WEB Catalog
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

Refrigerated Air Dryer/For Use in North, Central, and South America IDFB□E

Air Preparation Equipment » Air Dryers
    ・UL, CSA certified product
    ・Power supply voltage: Single-phase 115 VAC (60 Hz), 230 VAC (60 Hz)
     3-phase 460 VAC (60 Hz)
     
     Note) The air flow capacity for each dew point is indicated.

    ∗ The IDFB22E/37E series has been discontinued in August 2019.
     Please select the IDFB60/70 series.
Series Rated inlet condition Air flow capacity SCFM (m3/h [ANR] )
Outlet air pressure dew point Note)
37ºF(2.8℃)
Air flow capacity SCFM (m3/h [ANR] )
Outlet air pressure dew point Note)
45ºF(7.2℃)
Air flow capacity SCFM (m3/h [ANR] )
Outlet air pressure dew point Note)
50ºF(10℃)
Refrigerant Port size
IDFB3E 100ºF
(37.8℃)
100 psi
(0.7 MPa)
10(17) 11(19) 12(20) R134a
(HFC)
NPT3/8
IDFB4E 100ºF
(37.8℃)
100 psi
(0.7 MPa)
15(25) 16(27) 17(28) R134a
(HFC)
NPT1/2
IDFB6E 100ºF
(37.8℃)
100 psi
(0.7 MPa)
25(43) 26(45) 28(47) R134a
(HFC)
NPT3/4
IDFB8E 100ºF
(37.8℃)
100 psi
(0.7 MPa)
41(70) 43(74) 45(77) R134a
(HFC)
NPT3/4
IDFB11E 100ºF
(37.8℃)
100 psi
(0.7 MPa)
59(100) 62(106) 65(110) R134a
(HFC)
NPT3/4
IDFB15E 100ºF
(37.8℃)
100 psi
(0.7 MPa)
71(120) 80(136) 86(147) R134a
(HFC)
NPT1
IDFB22E 100ºF
(37.8℃)
100 psi
(0.7 MPa)
107(182) 120(205) 130(221) R134a
(HFC)
NPT1
IDFB37E 100ºF
(37.8℃)
100 psi
(0.7 MPa)
161(273) 173(294) 181(308) R134a
(HFC)
NPT1 1/2
IDFB55E 100ºF
(37.8℃)
100 psi
(0.7 MPa)
226(384) 258(438) 297(504) R407C
(HFC)
NPT2
IDFB75E 100ºF
(37.8℃)
100 psi
(0.7 MPa)
300(510) 353(600) 406(690) R407C
(HFC)
NPT2

Go Top

Go Top