Product Information » 
        WEB Catalog
                     » 
                            Switches/Sensors/Controller
                            
                     » 
                            Electronic Pressure Switches/Sensors (Self-contained Type)
                        
                            
                
                
                
                
                
                                    Electronic Pressure Switches/Sensors (Self-contained Type)
3-Screen Display High-Precision Digital Pressure Switch 
ZSE20□(F)/ISE20□
        
    - 
                
    ・Visualization of settings
 
・Simple 3-step setting
・Easy screen switching
It is possible to change the settings while checking the measured value.
・Delay time:1.5 ms or less
・Current consumption: 25 mA or less
・IO-Link compatible
                    Safety Instructions 
                    Pressure Switches/Flow Switches/Precautions 
                    Pressure Switch Series Variations/Application Example 
                    Glossary of Terms/Technical Information 
                    Green Procurement (RoHS) 
                
        
    | Series | Output type | Type | Rated pressure range | Enclosure | Applicable fluid | 
|---|---|---|---|---|---|
| ZSE20(F) ISE20  | 
                                    1 output | Compound pressure Vacuum pressure Positive pressure  | 
                                    −100.0 to 100.0 kPa 0.0 to −101.0 kPa −0.100 to 1.000 MPa  | 
                                    IP40 | Air | 
| ZSE20A(F) ISE20A  | 
                                    2 outputs Analog output (Voltage/Current)  | 
                                    Compound pressure Vacuum pressure Positive pressure  | 
                                    −100.0 to 100.0 kPa 0.0 to −101.0 kPa −0.100 to 1.000 MPa  | 
                                    IP40 | Air | 
| ZSE20B(F)-(L) ISE20B-(L)  | 
                                    2 outputs Analog output (Voltage/Current) IO-Link/Switch: 1 output  | 
                                    Compound pressure Vacuum pressure Positive pressure  | 
                                    −100.0 to 100.0 kPa 0.0 to −101.0 kPa −0.100 to 1.000 MPa  | 
                                    IP65 | Air | 
| ZSE20C(F)-(L) ISE20C(H)-(L)  | 
                                    2 outputs Analog output (Voltage/Current) IO-Link/Switch: 1 output  | 
                                    Compound pressure Vacuum pressure Positive pressure  | 
                                    −100.0 to 100.0 kPa 0.0 to −101.0 kPa −0.100 to 1.000 MPa −0.100 to 2.000 MPa  | 
                                    IP65 | General fluids | 
2-Color Display High-Precision Digital Pressure Switch ZSE30A(F)/ISE30A
                                - 
                
    ・With one-touch fitting (Straight, Elbow)
 
・Space-saving, capable of vertical and horizontal contact mounting
・With display calibration function
・Simultaneous copying is possible for maximum 10 units.
∗ The ZSE30A(F)/ISE30A series now features 2 new models:
the ZSE20(F)/ISE20 and the ZSE20A(F)/ISE20A.
▶Click here
                    Safety Instructions 
                    Pressure Switches/Flow Switches/Precautions 
                    Pressure Switch Series Variations/Application Example 
                    Glossary of Terms/Technical Information 
                    Green Procurement (RoHS) 
                
        
    | Series | Type | Rated pressure range | 
|---|---|---|
| ZSE30AF | Compound pressure | -100.0 to 100.0kPa | 
| ZSE30A | Vacuum pressure | 0.0 to -101.0kPa | 
| ISE30A | Positive pressure | -0.100 to 1.000MPa | 
2-Color Display High-Precision Digital Pressure Switch (for Low Pressure) ZSE30AF-X576 to X580
- 
                
    ・Able to detect and display pressures of 10 kPa or less
 
・Can copy to up to 10 switches simultaneously
Reduced setting time, Minimized risk of setting mistakes
・3-step setting
・With display low-cut function (zero-cut function)
“0” is displayed within the effective range.
                    Safety Instructions 
                    Pressure Switches/Flow Switches/Precautions 
                    Pressure Switch Series Variations/Application Example 
                    Glossary of Terms/Technical Information 
                    Green Procurement (RoHS) 
                
        
    | Series | Type | Rated pressure range | 
|---|---|---|
| ZSE30AF-X576 | Compound pressure | –500 to 500 Pa | 
| ZSE30AF-X577 | Compound pressure | –1.000 to 1.000 kPa | 
| ZSE30AF-X578 | Compound pressure | –2.00 to 2.00 kPa | 
| ZSE30AF-X579 | Compound pressure | –5.00 to 5.00 kPa | 
| ZSE30AF-X580 | Compound pressure | –10.00 to 10.00 kPa | 
Compact Digital Pressure Switch ZSE10(F)/ISE10
                                - 
                
    ・Low profile 9.8 mm
 
・Vertical mounting space reduced to approx. 1/2
(Compared to ZSE/ISE30A series)
・Simultaneous copying is possible for maximum 10 units.
・3-step setting
                    Safety Instructions 
                    Pressure Switches/Flow Switches/Precautions 
                    Pressure Switch Series Variations/Application Example 
                    Glossary of Terms/Technical Information 
                    Green Procurement (RoHS) 
                
        
    | Series | Type | Rated pressure range | 
|---|---|---|
| ZSE10F | Compound pressure | -100.0 to 100 kPa | 
| ZSE10 | Vacuum pressure | 0.0 to -101.0 kPa | 
| ISE10 | Positive pressure | -0.100 to 1.000 MPa | 
3-Screen Display High-Precision Digital Pressure Switch 
ISE7□/7□G/79S
        
    - 
                
    ・It is possible to change the settings while checking the measured value.
 
・IO-Link
・Angled display
Good visibility from various mounting positions
・Rotating display
Display can rotate 336 degrees after installation
・Applicable fluid:Air, Non-corrosive gas, Non-flammable gas (ISE70/71/79S)
:Liquid or gas that will not corrode materials of parts
in contact with fluid (ISE7□G)
                    Safety Instructions 
                    Pressure Switches/Flow Switches/Precautions 
                    Pressure Switch Series Variations/Application Example 
                    Glossary of Terms/Technical Information 
                    Green Procurement (RoHS) 
                
        
    | Series | Type | Rated pressure range | 
|---|---|---|
| ISE70 | Positive pressure (For air) | 0 to 1MPa | 
| ISE71 | Positive pressure (For air) | 0 to 1.6MPa | 
| ISE70G | Positive pressure (For general fluids) | 0 to 1MPa | 
| ISE75G | Positive pressure (For general fluids) | 0 to 2MPa | 
| ISE76G | Positive pressure (For general fluids) | 0 to 5MPa | 
| ISE77G | Positive pressure (For general fluids) | 0 to 10MPa | 
| ISE78G | Positive pressure (For general fluids) | 0 to 16MPa | 
| ISE79S | Positive pressure (For general fluids) | 0 to 50MPa | 
2-Color Display Digital Pressure Switch ISE70/75(H)
                                - 
                
    ・Metal body type (Aluminum die-casted)
 
・IP67
・With M12 connector
∗ The ISE70 series was discontinued in April 2018.
Please select the ISE70-□-L2 series.
∗ The ISE75 series was discontinued in July 2018.
Please select the ISE77G series.
∗ The ISE75H series was discontinued in December 2022.
Please select the ISE78G series.
                    Safety Instructions 
                    Pressure Switches/Flow Switches/Precautions 
                    Pressure Switch Series Variations/Application Example 
                    Glossary of Terms/Technical Information 
                    Green Procurement (RoHS) 
                
        
    | Series | Type | Rated pressure range | 
|---|---|---|
| ISE70 | Positive pressure (For air) | 0 to 1MPa | 
| ISE75 | Positive pressure (For general purpose fluids) | 0 to 10MPa | 
| ISE75H | Positive pressure (For general purpose fluids) | 0 to 15MPa | 
Air Checker/Electronic Pressure Switch PS1000/1100/1200
                                - 
                
    ・Plug-in port for One-touch fittings.
 
・With LED light.
                    Safety Instructions 
                    Pressure Switches/Flow Switches/Precautions 
                    Pressure Switch Series Variations/Application Example 
                    Glossary of Terms/Technical Information 
                    Green Procurement (RoHS) 
                
        
    | Series | Type | Set pressure range | 
|---|---|---|
| PS1000 | Positive pressure | -0.1 to 0.45 MPa | 
| PS1100 | For vacuum/residual pressure | -0.1 to 0.4 MPa | 
| PS1200 | For vacuum | -100 to 0 kPa | 
Compact Pressure Switch ZSE1/ISE1
                                - 
                
    ・Can be integrated with ZM ejector system.
            
 
                    Safety Instructions 
                    Pressure Switches/Flow Switches/Precautions 
                    Pressure Switch Series Variations/Application Example 
                    Glossary of Terms/Technical Information 
                    Green Procurement (RoHS) 
                
        
    | Series | Type | Set pressure range | 
|---|---|---|
| ZSE1 | Vacuum pressure | 0 to -101 kPa | 
| ISE1L | Positive pressure | 0 to 100 kPa | 
| ISE1 | Positive pressure | 0 to 1 MPa | 
Compact Pressure Switch ZSE2/ISE2
                                - 
                
    ・Can be integrated with a ZX or ZR ejector system
 
・Comes equipped with a suction filter as standard
                    Safety Instructions 
                    Pressure Switches/Flow Switches/Precautions 
                    Pressure Switch Series Variations/Application Example 
                    Glossary of Terms/Technical Information 
                    Green Procurement (RoHS) 
                
        
    | Series | Type | Set pressure range | 
|---|---|---|
| ZSE2 | Vacuum pressure | 0 to -101 kPa | 
| ISE2L | Positive pressure | 0 to 100 kPa | 
| ISE2 | Positive pressure | 0 to 1 MPa | 
3-Color Display Digital Gap Checker ISA3
- 
                
    ・Check at a glance to see if a workpiece is placed or not.
 
・The clearance distance between the detection surface and the workpiece can be found intuitively.
・Simple setting: Change the settings while checking the displayed value.
・Energy saving: Air consumption reduced by 60%
・Improved drainage resistance: 10 times or more
                    Safety Instructions 
                    Pressure Switches/Flow Switches/Precautions 
                    Pressure Switch Series Variations/Application Example 
                    Glossary of Terms/Technical Information 
                    Green Procurement (RoHS) 
                
        
    | Series | Rated distance range | Piping specifications: Supply side | Piping specifications: Detection side | 
|---|---|---|---|
| ISA3-F | 0.01 to 0.03 mm | Rc, G 1/8 | φ4, φ6 One-touch fitting, G 1/8 | 
| ISA3-G | 0.02 to 0.15 mm | Rc, G 1/8 | φ4, φ6 One-touch fitting, G 1/8 | 
| ISA3-H | 0.05 to 0.30 mm | Rc, G 1/8 | φ4, φ6 One-touch fitting, G 1/8 | 
3-Screen Display Digital Gap Checker/IO-Link Compatible ISA3-L
- 
                
    ・Monitoring the placement condition of the workpiece Indicates failure/abnormality
 
・Double sensor providing improved preventive and predictive maintenance (IoT) based on IO-Link
Process data provides Displayed value, Outlet pressure, and Supply pressure value.
・NPN/PNP switch function
・3-screen display (Setting)
・Window comparator type
・Zero cut-off range can be changed.
▶IO-Link Master
                    Safety Instructions 
                    Pressure Switches/Flow Switches/Precautions 
                    Pressure Switch Series Variations/Application Example 
                    Glossary of Terms/Technical Information 
                    Green Procurement (RoHS) 
                    IO-Link Master 
                
        
    | Series | Rated distance range | Piping specifications: Supply side | Piping specifications: Detection side | 
|---|---|---|---|
| ISA3-F□L | 0.01 to 0.03 mm | Rc, G 1/8 | φ4, φ6 One-touch fitting, G 1/8 | 
| ISA3-G□L | 0.02 to 0.15 mm | Rc, G 1/8 | φ4, φ6 One-touch fitting, G 1/8 | 
| ISA3-H□L | 0.05 to 0.30 mm | Rc, G 1/8 | φ4, φ6 One-touch fitting, G 1/8 | 
Digital Pressure Switch (Built-in Regulator Type) ISE35
                                - 
                
    ・Modular type mountable
 
・ARM10/11 series mountable
・Selectable pressure unit
・With anti-chattering function
・Power-saving mode
                    Safety Instructions 
                    Pressure Switches/Flow Switches/Precautions 
                    Pressure Switch Series Variations/Application Example 
                    Glossary of Terms/Technical Information 
                    Green Procurement (RoHS) 
                
        
    | Series | Type | Rated pressure range | 
|---|---|---|
| ISE35 | Positive pressure | -0.1 to 1 MPa | 
Digital Pressure Sensor GS40
                                - 
                
    ・A pressure switch function has been added to the gauge with a digital display.
            
 
| Series | Set pressure (MPa) | 
|---|---|
| GS40 | 0 to 0.98 | 
















                            
                
                            
                
                            
                
                            
                
                            
                
