Refrigerated Air Dryer IDF
-
・Applicable for the high-temperature environments
Ambient temperature : Max. 45℃
Inlet air temperature : Max. 65℃
・Increased air flow capacity
Safety Instructions
Air Preparation Equipment/Precautions
Model Selection Guide/Quick Reference Guide
Green Procurement (RoHS)
Series | Rated inlet condition |
Air flow capacity (m3/min[ANR]) 50 Hz |
Air flow capacity (m3/min[ANR]) 60 Hz |
Refrigerant | Port size |
---|---|---|---|---|---|
IDF60 | 35℃ 0.7 MPa |
5.6 | 6.5 | R410A(HFC) GWP:2088 |
R1 |
IDF70 | 35℃ 0.7 MPa |
8 | 9.1 | R410A(HFC) GWP:2088 |
R1 1/2 |
IDF80 | 40℃ 0.7 MPa |
11.6 | 13.6 | R410A(HFC) GWP:2088 |
R2 |
IDF90 | 40℃ 0.7 MPa |
14.3 | 16.4 | R410A(HFC) GWP:2088 |
R2 |
Refrigerated Air Dryer IDF □E/F/D
-
* The production of the IDF22E to IDF75E series was scheduled to end in
June 2022, but will be extended. We will announce the production end
date separately.
Click here for the IDF22E to IDF75E series catalog.
Safety Instructions
Air Preparation Equipment/Precautions
Model Selection Guide/Quick Reference Guide
Green Procurement (RoHS)
Series | Rated inlet condition | Air flow capacity (m3/min[ANR]) 50 Hz |
Air flow capacity (m3/min[ANR]) 60 Hz |
Applicable air compressor (kW) | Refrigerant | Port size |
---|---|---|---|---|---|---|
IDF1E | 35℃ 0.7 MPa |
0.1 | 0.12 | 0.75 | R134a (HFC) |
Rc3/8 |
IDF2E | 35℃ 0.7 MPa |
0.2 | 0.235 | 1.5 | R134a (HFC) |
Rc3/8 |
IDF3E | 35℃ 0.7 MPa |
0.32 | 0.37 | 2.2 | R134a (HFC) |
Rc3/8 |
IDF4E | 35℃ 0.7 MPa |
0.52 | 0.57 | 3.7 | R134a (HFC) |
Rc1/2 |
IDF6E | 35℃ 0.7 MPa |
0.75 | 0.82 | 5.5 | R134a (HFC) |
Rc3/4 |
IDF8E | 35℃ 0.7 MPa |
1.22 | 1.32 | 7.5 | R134a (HFC) |
Rc3/4 |
IDF11E | 35℃ 0.7 MPa |
1.65 | 1.82 | 11 | R134a (HFC) |
Rc3/4 |
IDF15E1 | 35℃ 0.7 MPa |
2.8 | 3.1 | 15 | R134a (HFC) |
Rc1 |
IDF22E | 35℃ 0.7 MPa |
3.9 | 4.3 | 22 | R407C (HFC) |
R1 |
IDF37E | 35℃ 0.7 MPa |
5.7 | 6.1 | 37 | R407C (HFC) |
R1 1/2 |
IDF55E | 40℃ 0.7 MPa |
8.4 | 9.8 | 55 | R407C (HFC) |
R2 |
IDF75E | 40℃ 0.7 MPa |
11.0 | 12.4 | 75 | R407C (HFC) |
R2 |
IDF100F | 40℃ 0.7 MPa |
16.0 | 18.8 | 100 | R407C (HFC) |
R2 |
IDF125F | 40℃ 0.7 MPa |
20.1 | 23.7 | 125 | R407C (HFC) |
65(2 1/2B) flange |
IDF150F | 40℃ 0.7 MPa |
25.0 | 30.0 | 150 | R407C (HFC) |
80(3B) flange |
IDF190D | 40℃ 0.7 MPa |
32.0 | 38.0 | 190 | R407C (HFC) |
80(3B) flange |
IDF240D | 40℃ 0.7 MPa |
43.0 | 50.0 | 240 | R407C (HFC) |
100(4B) flange |
IDF370D | 35℃ 0.7 MPa |
54.0 | 65.0 | 370 | R407C (HFC) |
150(6B) flange |
Refrigerated Air Dryer IDU □E
Safety Instructions
Air Preparation Equipment/Precautions
Model Selection Guide/Quick Reference Guide
Green Procurement (RoHS)
Series | Rated inlet condition | Air flow capacity (m3/min[ANR]) 50 Hz |
Air flow capacity (m3/min[ANR]) 60 Hz |
Applicable air compressor (kW) | Refrigerant | Port size |
---|---|---|---|---|---|---|
IDU3E | 55℃ 0.7 MPa |
0.32 | 0.37 | 2.2 | R134a (HFC) |
Rc3/8 |
IDU4E | 55℃ 0.7 MPa |
0.52 | 0.57 | 3.7 | R134a (HFC) |
Rc1/2 |
IDU6E | 55℃ 0.7 MPa |
0.75 | 0.82 | 5.5 | R134a (HFC) |
Rc3/4 |
IDU8E | 55℃ 0.7 MPa |
1.1 | 1.2 | 7.5 | R134a (HFC) |
Rc3/4 |
IDU11E | 55℃ 0.7 MPa |
1.5 | 1.7 | 11 | R134a (HFC) |
Rc3/4 |
IDU15E1 | 55℃ 0.7 MPa |
2.6 | 2.8 | 15 | R134a (HFC) |
Rc1 |
IDU22E | 55℃ 0.7 MPa |
3.9 | 4.3 | 22 | R407C (HFC) |
R1 |
IDU37E | 55℃ 0.7 MPa |
5.7 | 6.1 | 37 | R407C (HFC) |
R1 1/2 |
IDU55E | 55℃ 0.7 MPa |
8.4 | 9.8 | 55 | R407C (HFC) |
R2 |
IDU75E | 55℃ 0.7 MPa |
11.0 | 12.5 | 75 | R407C (HFC) |
R2 |
Refrigerated Air Dryer/Double Energy Saving Function Series IDF100FS/125FS/150FS
-
・Energy-saving design (Second re-heater + Digital scroll compressor)
・Power consumption: Reduced by up to 76%
・Exhaust heat: Reduced by up to 25%
・Tolerant of high temperature environments!
・Ambient temperature: Up to 45ºC, Inlet air temperature: Up to 60ºC
Safety Instructions
Air Preparation Equipment/Precautions
Model Selection Guide/Quick Reference Guide
Green Procurement (RoHS)
Series | Applicable compressor (kW) |
Air flow capacity (m3/min[ANR]) 50 Hz |
Air flow capacity (m3/min[ANR]) 60 Hz |
---|---|---|---|
IDF100FS | 100 | 16 | 18.8 |
IDF125FS | 125 | 20.1 | 23.7 |
IDF150FS | 150 | 25 | 27 |
Refrigerated Air Dryer/For Use in Southeast Asia IDFC□
-
・Applicable for the high-temperature environments of tropical regions
・Can be used in high-temperature environments
Ambient temperature : Max. 45℃
Inlet air temperature : Max. 65℃
Dew point range : 3℃ to 20℃
・Air flow capacity : 9.2 m3/min (52% increase compared to the current model)
・Power supply voltage : Single-phase 230 VAC (50 Hz)
Safety Instructions
Air Preparation Equipment/Precautions
Model Selection Guide/Quick Reference Guide
Green Procurement (RoHS)
Series | Rated inlet condition | Air flow capacity (m3/min [ANR] ) Outlet air pressure dew point 3℃ |
Air flow capacity (m3/min [ANR] ) Outlet air pressure dew point 10℃ |
Air flow capacity (m3/min [ANR] ) Outlet air pressure dew point 20℃ |
Refrigerant | Port size |
---|---|---|---|---|---|---|
IDFC60 | 50℃ 0.7 MPa |
0.9 | 2.8 | 4.7 | R410A(HFC) GWP:2088 |
R1 |
IDFC70 | 50℃ 0.7 MPa |
1.6 | 4.7 | 7.8 | R410A(HFC) GWP:2088 |
R1 1/2 |
IDFC80 | 50℃ 0.7 MPa |
2.2 | 6.5 | 10.9 | R410A(HFC) GWP:2088 |
R2 |
IDFC90 | 50℃ 0.7 MPa |
3.1 | 9.2 | 15.4 | R410A(HFC) GWP:2088 |
R2 |
Refrigerated Air Dryer/For Use in Europe, Asia and Oceania IDFA
-
・Applicable for the high-temperature environments
Ambient temperature : Max. 45℃
Inlet air temperature : Max. 65℃
・Increased air flow capacity
・Power supply voltage: Single-phase 230 VAC (50 Hz)
Safety Instructions
Air Preparation Equipment/Precautions
Model Selection Guide/Quick Reference Guide
Green Procurement (RoHS)
Series | Rated inlet condition |
Air flow capacity (m3/h [ANR] ) Dew point 3℃ |
Air flow capacity (m3/h [ANR] ) Dew point 7℃ |
Air flow capacity (m3/h [ANR] ) Dew point 10℃ |
Refrigerant | Port size |
---|---|---|---|---|---|---|
IDFA60 | 35℃ 0.7 MPa |
204 | 300 | 360 | R410A(HFC) GWP:2088 |
R1 |
IDFA70 | 35℃ 0.7 MPa |
312 | 408 | 480 | R410A(HFC) GWP:2088 |
R1 1/2 |
IDFA80 | 35℃ 0.7 MPa |
552 | 654 | 720 | R410A(HFC) GWP:2088 |
R2 |
IDFA90 | 35℃ 0.7 MPa |
810 | 900 | 960 | R410A(HFC) GWP:2088 |
R2 |
Refrigerated Air Dryer/For Use in Europe, Asia, and Oceania IDFA□E/F
-
・EC Directive compliant product (With CE mark)
・Power supply voltage: Single-phase 230 VAC (50 Hz)
* The production of the IDFA22E to IDFA75E series was scheduled to end
in June 2022, but will be extended. We will announce the production end
date separately.
Click here for the IDFA22E to IDFA75E series catalog.
Safety Instructions
Air Preparation Equipment/Precautions
Model Selection Guide/Quick Reference Guide
Green Procurement (RoHS)
Series | Rated inlet condition | Air flow capacity (m3/h [ANR] ) Outlet air pressure dew point 3℃ |
Air flow capacity (m3/h [ANR] ) Outlet air pressure dew point 7℃ |
Air flow capacity (m3/h [ANR] ) Outlet air pressure dew point 10℃ |
Refrigerant | Port size |
---|---|---|---|---|---|---|
IDFA3E | 35℃ 0.7 MPa |
12 | 15 | 17 | R134a (HFC) |
Rc3/8 |
IDFA4E | 35℃ 0.7 MPa |
24 | 31 | 34 | R134a (HFC) |
Rc1/2 |
IDFA6E | 35℃ 0.7 MPa |
36 | 46 | 50 | R134a (HFC) |
Rc3/4 |
IDFA8E | 35℃ 0.7 MPa |
65 | 83 | 91 | R134a (HFC) |
Rc3/4 |
IDFA11E | 35℃ 0.7 MPa |
80 | 101 | 112 | R134a (HFC) |
Rc3/4 |
IDFA15E | 35℃ 0.7 MPa |
120 | 152 | 168 | R134a (HFC) |
Rc1 |
IDFA22E | 35℃ 0.7 MPa |
182 | 231 | 254 | R407C (HFC) |
R1 |
IDFA37E | 35℃ 0.7 MPa |
273 | 347 | 382 | R407C (HFC) |
R1 1/2 |
IDFA55E | 35℃ 0.7 MPa |
390 | 432 | 510 | R407C (HFC) |
R2 |
IDFA75E | 35℃ 0.7 MPa |
660 | 720 | 822 | R407C (HFC) |
R2 |
IDFA100F-38 | 40℃ 0.7 MPa |
- | - | 960 | R407C (HFC) |
R2 |
IDFA125F-38 | 40℃ 0.7 MPa |
- | - | 1210 | R407C (HFC) |
R2 1/2 |
IDFA150F-38 | 40℃ 0.7 MPa |
- | - | 1500 | R407C (HFC) |
DIN flange 80 |
IDFA100F-40 | 35℃ 0.7 MPa |
860 | - | - | R407C (HFC) |
R2 |
IDFA125F-40 | 35℃ 0.7 MPa |
1100 | - | - | R407C (HFC) |
R2 1/2 |
IDFA150F-40 | 35℃ 0.7 MPa |
1340 | - | - | R407C (HFC) |
DIN flange 80 |
Refrigerated Air Dryer/For Use in North, Central and South America IDFB
-
・Applicable for the high-temperature environments
Ambient temperature : Max. 113ºF (45ºC)
Inlet air temperature : Max. 149ºF (65ºC)
・Increased air flow capacity
・Power supply voltage: Single-phase 230 VAC (60 Hz)
Safety Instructions
Air Preparation Equipment/Precautions
Model Selection Guide/Quick Reference Guide
Green Procurement (RoHS)
Series | Rated inlet condition |
Air flow capacity (m3/h [ANR] ) Dew point 37ºF (2.8℃) |
Air flow capacity (m3/h [ANR] ) Dew point 45ºF (7.2℃) |
Air flow capacity (m3/h [ANR] ) Dew point 50ºF (10℃) |
Refrigerant | Port size |
---|---|---|---|---|---|---|
IDFB60 | 100ºF (37.8℃) 100 psi (0.7 MPa) |
113 (192) |
155 (264) |
177 (300) |
R410A(HFC) GWP:2088 |
R1, NPT1 |
IDFB70 | 100ºF (37.8℃) 100 psi (0.7 MPa) |
166 (282) |
215 (366) |
251 (426) |
R410A(HFC) GWP:2088 |
R1 1/2, NPT1 1/2 |
IDFB80 | 100ºF (37.8℃) 100 psi (0.7 MPa) |
247 (420) |
314 (534) |
353 (600) |
R410A(HFC) GWP:2088 |
R2, NPT2 |
IDFB90 | 100ºF (37.8℃) 100 psi (0.7 MPa) |
335 (570) |
406 (690) |
459 (780) |
R410A(HFC) GWP:2088 |
R2, NPT2 |
Refrigerated Air Dryer/For Use in North, Central, and South America IDFB□E
-
・UL, CSA certified product
・Power supply voltage: Single-phase 115 VAC (60 Hz), 230 VAC (60 Hz)
3-phase 460 VAC (60 Hz)
Note) The air flow capacity for each dew point is indicated.
∗ The IDFB22E/37E series has been discontinued in August 2019.
Please select the IDFB60/70 series.
Safety Instructions
Air Preparation Equipment/Precautions
Model Selection Guide/Quick Reference Guide
Green Procurement (RoHS)
Series | Rated inlet condition | Air flow capacity SCFM (m3/h [ANR] ) Outlet air pressure dew point Note) 37ºF(2.8℃) |
Air flow capacity SCFM (m3/h [ANR] ) Outlet air pressure dew point Note) 45ºF(7.2℃) |
Air flow capacity SCFM (m3/h [ANR] ) Outlet air pressure dew point Note) 50ºF(10℃) |
Refrigerant | Port size |
---|---|---|---|---|---|---|
IDFB3E | 100ºF (37.8℃) 100 psi (0.7 MPa) |
10(17) | 11(19) | 12(20) | R134a (HFC) |
NPT3/8 |
IDFB4E | 100ºF (37.8℃) 100 psi (0.7 MPa) |
15(25) | 16(27) | 17(28) | R134a (HFC) |
NPT1/2 |
IDFB6E | 100ºF (37.8℃) 100 psi (0.7 MPa) |
25(43) | 26(45) | 28(47) | R134a (HFC) |
NPT3/4 |
IDFB8E | 100ºF (37.8℃) 100 psi (0.7 MPa) |
41(70) | 43(74) | 45(77) | R134a (HFC) |
NPT3/4 |
IDFB11E | 100ºF (37.8℃) 100 psi (0.7 MPa) |
59(100) | 62(106) | 65(110) | R134a (HFC) |
NPT3/4 |
IDFB15E | 100ºF (37.8℃) 100 psi (0.7 MPa) |
71(120) | 80(136) | 86(147) | R134a (HFC) |
NPT1 |
IDFB22E | 100ºF (37.8℃) 100 psi (0.7 MPa) |
107(182) | 120(205) | 130(221) | R134a (HFC) |
NPT1 |
IDFB37E | 100ºF (37.8℃) 100 psi (0.7 MPa) |
161(273) | 173(294) | 181(308) | R134a (HFC) |
NPT1 1/2 |
IDFB55E | 100ºF (37.8℃) 100 psi (0.7 MPa) |
226(384) | 258(438) | 297(504) | R407C (HFC) |
NPT2 |
IDFB75E | 100ºF (37.8℃) 100 psi (0.7 MPa) |
300(510) | 353(600) | 406(690) | R407C (HFC) |
NPT2 |
Thermo-dryer with Air Temperature Adjustment Function IDH□
-
・Stable supply of temperature and pressure controlled dry clean air
Can supply compressed air with the same conditions and quality regardless of
the season
・Application example:
Supplying compressed air with constant conditions to air bearings mounted on
a tool
・Built-in filter
Nominal filtration: 0.01 μm (99.9% filtration efficiency)
Outlet oil mist concentration: Max. 0.01 mg/m3 (ANR)
Outlet cleanliness: Particles of 0.3 μm or more: 3.5 particles/L (ANR) or less
・Compatible with power supplies from around the world Single-phase 100, 200,
230 VAC (50/60 Hz)
Safety Instructions
Air Preparation Equipment/Precautions
Model Selection Guide/Quick Reference Guide
Green Procurement (RoHS)
Series | Air flow capacity L/min(ANR) |
Outlet air temperature adjustment range |
Outlet air set pressure range |
Outlet air temperature stability |
Cooling method |
---|---|---|---|---|---|
IDH□4 | 100 to 500 | 15 to 30℃ | 0.15 to 0.85 MPa | ±0.1 | Heater operation PID control |
IDH□6 | 200 to 800 | 15 to 30℃ | 0.15 to 0.85 MPa | ±0.1 | Heater operation PID control |
Heatless Air Dryer ID
-
・Can supply dry air with a low dew point below –30ºC
・Compact and lightweight without a heater or an electric control board
・It is possible to check the outlet dew point with the indicator.
(Self-regenerative type allows for easy maintenance)
Safety Instructions
Air Preparation Equipment/Precautions
Model Selection Guide/Quick Reference Guide
Green Procurement (RoHS)
Series | Outlet flow L/min (ANR) | Inlet flow L/min (ANR) |
---|---|---|
ID | 80 to 780 | 100 to 975 |
Membrane Air Dryer IDG□A/IDG
-
・It is possible to easily supply dry air using the hollow fiber membrane.
・Non-fluorocarbon
・Power supply not required
・Compatible with low dew points (–60ºC)
・No vibration or heat discharge
・With a dew point indicator
Safety Instructions
Air Preparation Equipment/Precautions
Model Selection Guide/Quick Reference Guide
Green Procurement (RoHS)
Series | Outlet flow L/min (ANR) | Standard dew point (°C) |
---|---|---|
IDG□A/IDG | 10 to 1000 | -15,-20,-40,-60 |
Moisture Control Tube IDK
-
・Prevents condensation in piping for small cylinders/air grippers
・Diffuses water vapor in the piping to the outside
・All you have to do is install the moisture control tube.
Additional power supplies and works are not necessary.
Series | O.D./I.D. (mm) | Effective length (mm) | Applicable fittings |
---|---|---|---|
IDK02 Linear shape |
2/1.2 | 100 200 |
KQ2 |
IDK04 Linear shape |
4/2.5 | 100 200 |
KQ2 |
IDK06 Linear shape |
6/4 | 100 200 |
KQ2 |
IDK04-100-C1 Coil shape |
4/2.5 | 100 | KQ2 |