Product Information »
WEB Catalog
»
Industrial Device Communication Equipment/Wireless System
»
Industrial Device Communication Equipment: CC-Link Compatible Products
Industrial Device Communication Equipment: CC-Link Compatible Products
Serial Transmission System EX260
-
For Output
∗The applicable protocols differ depending on the series.
For details, refer to the catalog of each series.
・IP67
・RJ45 communication connectors (X205)
▶IO-Link Master
Safety Instructions
3/4/5 Port Solenoid Valves/Precautions
Fieldbus System Precautions
Industrial IoT Cybersecurity
Glossary of Fieldbus Terms
Series Variations/Applicable Valve Series
Safety over Fieldbus with PROFIsafe
Green Procurement (RoHS)
IO-Link Master
Series | Enclosure | Communication protocol∗ | Applicable valve |
---|---|---|---|
EX260 | IP67 | DeviceNet™ PROFIBUS DP CC-Link EtherCAT PROFINET EtherNet/IP™ Ethernet POWERLINK IO-Link (Only available for SY, JSY, VQC communication connectors) PROFIsafe (Only available for SY, JSY, VQC communication connectors) |
SY3000,5000,7000 (Plug-in) JSY1000,3000,5000 (Plug-in) VQC1000,2000,4000,5000 SV1000,2000,3000 S0700(IP40) |
Serial Transmission System EX120/121/122/124/126/140/180
-
For Output
∗The applicable protocols differ depending on the series.
For details, refer to the catalog of each series.
∗The NKE Corp. Fieldbus H System was discontinued in February 2021.
Please consider switching to a different network.
Safety Instructions
3/4/5 Port Solenoid Valves/Precautions
Fieldbus System Precautions
Industrial IoT Cybersecurity
Glossary of Fieldbus Terms
Series Variations/Applicable Valve Series
Green Procurement (RoHS)
Series | Enclosure | Communication protocol∗ | Applicable valve |
---|---|---|---|
EX120 | IP20 | DeviceNet™ CC-Link CompoNet™ CompoBus/S NKE (Wiring saving system) S-LINK V (Made to order) |
JSY1000, 3000, 5000 (Plug-in) SY3000,5000,7000 (Plug-in) VQ1000,2000 SV1000,2000,3000,4000 |
EX121 | IP20 | DeviceNet™ CC-Link CompoNet™ CompoBus/S NKE (Wiring saving system) S-LINK V (Made to order) |
SY3000,5000 |
EX122 | IP20 | DeviceNet™ CC-Link CompoNet™ CompoBus/S NKE (Wiring saving system) S-LINK V (Made to order) |
SY3000,5000 |
EX124 | IP65 | CC-Link CompoBus/S DeviceNet™ (Made to order) |
VQ2000,4000,5000 |
EX126 | IP67 | CC-Link | SY3000,5000,7000 (Plug-in) SV1000,2000,3000 VQC1000,2000,4000, 5000 |
EX140 | IP20 | DeviceNet™ CC-Link CompoBus/S NKE(Wiring saving system) |
SZ3000 SQ1000,2000 |
EX180 | IP20 | DeviceNet™ CC-Link EtherCAT (Made to order) AnyWireASLINK (Made to order) |
SY3000,5000,7000 SJ2000,3000 S0700 |
Serial Transmission System EX600
-
For Input/Output
∗The applicable protocols differ depending on the series.
For details, refer to the catalog of each series.
▶IO-Link Devices
Safety Instructions
3/4/5 Port Solenoid Valves/Precautions
Fieldbus System Precautions
Industrial IoT Cybersecurity
Glossary of Fieldbus Terms
Series Variations/Applicable Valve Series
Green Procurement (RoHS)
Series | Enclosure | Communication protocol∗ | Applicable valve |
---|---|---|---|
EX600 | IP67 | PROFIBUS DP DeviceNet™ CC-Link EtherNet/IP™ EtherCAT PROFINET PROFINET (IO-Link unit compatible) MRP (PROFINET) (Made to order) Ethernet POWERLINK (Made to order) Modbus TCP (Made to order) CC-Link IE Field (Made to order) EtherNet/IP™ (IO-Link master compatible) (Made to order) |
JSY1000, 3000, 5000 (Plug-in) SY3000,5000,7000 (Plug-in) SV1000,2000,3000 VQC1000,2000,4000,5000 S0700(IP40) |
Serial Transmission System EX510
-
For Input/Output, Gateway Type
∗The applicable protocols differ depending on the series.
For details, refer to the catalog of each series.
Safety Instructions
3/4/5 Port Solenoid Valves/Precautions
Fieldbus System Precautions
Industrial IoT Cybersecurity
Glossary of Fieldbus Terms
Series Variations/Applicable Valve Series
Green Procurement (RoHS)
Series | Enclosure | Communication protocol∗ | Applicable valve |
---|---|---|---|
EX510 | IP20 | CC-Link DeviceNet™ PROFIBUS DP EtherNet/IP™ (Made to order) PROFINET (Made to order) |
SJ2000,3000 SY3000,5000,7000 (Plug-in) SY3000,5000,7000,9000 SYJ3000,5000,7000 SQ1000,2000 SZ3000 VQ1000,2000 VQZ1000,2000,3000 S0700 |
Wireless System EXW1/EX600-W
-
・Noise resistance
Uses the 2.4 GHz ISM frequency band
Frequency hopping: Every 2 ms (Fastest)
・Communication cables not required
Reduced wiring work, space, and cost
Minimized disconnection risk
・Provides communication stability in FA environments
・Compact and lightweight (EXW1)
Volume: Approx. 86% reduction, Weight: Approx. 87% reduction
・Modular connection is possible. (EX600-W)
▶IO-Link Master
Safety Instructions
3/4/5 Port Solenoid Valves/Precautions
Fieldbus System Precautions
Industrial IoT Cybersecurity
Glossary of Fieldbus Terms
Green Procurement (RoHS)
Series | Enclosure | Communication protocol | Applicable valve |
---|---|---|---|
EXW1 | IP20 (Remote) | CC-Link | JSY1000, 3000, 5000 |
EX600-W | IP67 equivalent | EtherNet/IP™ PROFINET |
JSY1000, 3000, 5000(Plug-in) SY3000,5000,7000(Plug-in) SV1000,2000,3000 S0700(IP40) VQC1000,2000,4000,5000 |
Step Motor Controller JXCE1/91/P1/D1/L□/M1
-
・EtherCAT, EtherNet/IP™, PROFINET, DeviceNet®,
IO-Link, and CC-Link compatible
・Two types of operation command:
Step no. defined operation, Numerical data defined operation
・Transition wiring of communication cables
・Numerical monitoring available
・IO-Link communication can be performed.
・Controller with STO sub-function/JXC□F
Safety Instructions
Electric Actuators/Precautions
Features
Series Variations
Simplified Selection Flow Chart
Green Procurement (RoHS)
CE/UL-compliance List
Series | Compatible motor |
Power supply voltage |
Fieldbus |
---|---|---|---|
JXCE1 (Standard) JXCEF (With subfunction) |
Step motor (Servo/24 VDC) |
24 VDC ±10% |
EtherCAT™ |
JXC91 (Standard) JXC9F (With subfunction) |
Step motor (Servo/24 VDC) |
24 VDC ±10% |
EtherNet/IP™ |
JXCP1 (Standard) JXCPF (With subfunction) |
Step motor (Servo/24 VDC) |
24 VDC ±10% |
PROFINET |
JXCD1 (Standard) | Step motor (Servo/24 VDC) |
24 VDC ±10% |
DeviceNet™ |
JXCL1 (Standard) JXCLF (With subfunction) |
Step motor (Servo/24 VDC) |
24 VDC ±10% |
IO-Link |
JXCM1 (Standard) | Step motor (Servo/24 VDC) |
24 VDC ±10% |
CC-Link |
AC Servo Motor Driver LECS
-
・Pulse input type motor driver
・Compatible motor capacity: 100 W, 200 W, 400 W
・Compatible encoders:
Incremental type
Absolute type
・Servo adjustment using auto gain tuning
・With display setting function
・Positioning by up to 255 point tables
Safety Instructions
Electric Actuators/Precautions
Features
Series Variations
Simplified Selection Flow Chart
Wiring Method
Green Procurement (RoHS)
CE/UL-compliance List
Type | Model | Compatible motor |
Power supply voltage |
Parallel input/output Input |
Parallel input/output Output |
---|---|---|---|---|---|
Pulse input type (For incremental encoder) |
LECSA | AC servo motor (100/200/400 W) |
100 to 120 VAC (50/60 Hz) 200 to 230 VAC (50/60 Hz) |
6 | 4 |
Pulse input type (For absolute encoder) |
LECSB | AC servo motor (100/200/400 W) |
100 to 120 VAC (50/60 Hz) 200 to 230 VAC (50/60 Hz) |
10 | 6 |
CC-Link direct input type (For absolute encoder) |
LECSC | AC servo motor (100/200/400 W) |
100 to 120 VAC (50/60 Hz) 200 to 230 VAC (50/60 Hz) |
― | ― |
SSCNETⅢ type (For absolute encoder) |
LECSS | AC servo motor (100/200/400 W) |
100 to 120 VAC (50/60 Hz) 200 to 230 VAC (50/60 Hz) |
― | ― |
Pulse input type/ Positioning type (For absolute encoder) |
LECSB-T | AC servo motor (100/200/400 W) |
200 to 240 VAC (50/60 Hz) |
10 | 6 |
CC-Link direct input type (For absolute encoder) |
LECSC-T | AC servo motor (100/200/400 W) |
200 to 230 VAC (50/60 Hz) |
― | ― |
Network card type/H type (For absolute encoder) |
LECSN-T | AC servo motor (100/200/400 W) |
200 to 240 VAC (50/60 Hz) |
― | ― |
SSCNETⅢ type/H type (For absolute encoder) |
LECSS-T | AC servo motor (100/200/400 W) |
200 to 240 VAC (50/60 Hz) |
― | ― |
Fieldbus-compatible Gateway (GW) Unit LEC-G
-
・The LE□ series electric actuators are applicable to Fieldbus protocols.
・Conversion unit for Fieldbus network and LEC serial communication
・2 methods of operation:
Step data input, numerical data input
・Position, speed, and other values can be checked on the PLC.
Safety Instructions
Electric Actuators/Precautions
Features
Series Variations
Simplified Selection Flow Chart
Wiring Method
Green Procurement (RoHS)
CE/UL-compliance List
Series | Applicable fieldbus | Power supply voltage | Applicable controllers |
---|---|---|---|
LEC-G | CC-Link DeviceNet™ PROFIBUS DP EtherNet/IP™ |
24 VDC ±10% |
LECA6 series |
Electro-Pneumatic Regulator ITV
-
・Stepless control of air pressure in proportion to electrical signals
・Sensitivity: 0.2 kPa (100 kPa specification)
・Linearity: ±1% or less (F.S.)
・Hysteresis: 0.5% or less (F.S.)
・Communication: CC-Link, DeviceNet™, PROFIBUS DP, RS-232C, IO-Link
▶IO-Link Master
Safety Instructions
F.R.L. Units/Precautions
Series Variations/Pressure Control Equipment
Green Procurement (RoHS)
IO-Link Master
Series | Port size | Set pressure (MPa) |
---|---|---|
ITV0000 | Built-in One-touch fitting φ4,φ5/32 |
0.001 to 0.1 0.001 to 0.5 0.001 to 0.9 |
ITV1000 | 1/8,1/4 | 0.005 to 0.1 0.005 to 0.5 0.005 to 0.9 |
ITV2000 | 1/4,3/8 | 0.005 to 0.1 0.005 to 0.5 0.005 to 0.9 |
ITV3000 | 1/4,3/8,1/2 | 0.005 to 0.1 0.005 to 0.5 0.005 to 0.9 |
Electronic Vacuum Regulator ITV
-
・Stepless control of vacuum pressure in proportion to electrical signals
・Communication: CC-Link, DeviceNet™, PROFIBUS DP, RS-232C
Safety Instructions
F.R.L. Units/Precautions
Series Variations/Pressure Control Equipment
Green Procurement (RoHS)
Series | Port size | Set pressure (MPa) |
---|---|---|
ITV009□ | Built-in One-touch fitting φ4,φ5/32 |
-1 to -100 |
ITV209□ | 1/4 | -1.3 to -80 |