WEB Catalog

Product Information »  WEB Catalog  »  Vacuum Equipment (Vacuum Generators/Vacuum Suction Cups/Other)  »  Vacuum Ejectors (Vacuum Generators)/Vacuum Pump Systems

Vacuum Ejectors (Vacuum Generators)/Vacuum Pump Systems

Multistage Ejector (Vacuum Generators) ZL1/ZL3/ZL6

    ・Max. suction flow rate: 3 types available: 100, 300, and 600 L/min (ANR)
    ・Air consumption: 90% reduction (For the ZL3, ZL6)
    ・Weight: Max. 60% reduction [ZL112 (Existing model): 450 g R ZL1: 180 g]
    ・3-stage diffuser construction (For the ZL1:SMC comparison)
     Suction flow rate increased by 250%
    ・3 types of vacuum pressure sensors
    ・No tools are required! Maintenance labor can be reduced.

    *1 ZL3H, ZL6H (Standard supply pressure: 0.5 MPa)
    *2 Branch + Port exhaust
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
  • Multistage Ejector (Vacuum Generators) ZL1/ZL3/ZL6
    Manual
    Series Nozzle diameter
    (mm)
    View search result
    ZL1 1.2 View search result
    ZL3 1.9
    1.5
    ZL6 1.9 x 2
    1.5 x 2
  • Multistage Ejector (Vacuum Generators) ZL1/ZL3/ZL6
    DoC
    Series Nozzle diameter
    (mm)
    View search result
    ZL1 1.2 View search result
    ZL3 1.9
    1.5
    View search result
    ZL6 1.9 x 2
    1.5 x 2
    View search result
Series Nozzle diameter
(mm)
Max. suction flow
[L/min(ANR)]
Air consumption
[L/min(ANR)]
ZL1 1.2 100 57
ZL3 1.9
1.5
300∗2 135∗1
ZL6 1.9 x 2
1.5 x 2
600∗2 270∗1

Features

Compact3 types available: 100, 300, and 600 L/min (ANR)

Energy saving(ZL3、ZL6)

High efficiency (Suction flow rate/Air consumption)(ZL1、ZL3、ZL6)

3-stage diffuser construction(ZL1、ZL3、ZL6)

Applications

Various vacuum pressure sensors(ZL1、ZL3、ZL6)

Vacuum port: A branch specification is selectable.(ZL3、ZL6)

Standard supply pressure: A 0.35 MPa specification has been added. (ZL3、ZL6)

Supports the adoption of low supply pressure



No tools are required! Reduced maintenance labor(ZL1)

Supply valve/Release valve

Variations

Go Top

Go Top