|Air Preparation Filters
-
How is the accumulated drainage discharged from AMG series water separators?
-
The method of discharging the accumulated drainage is different depending on the presence or absence of an auto drain function.
Without auto drain: Drain can be discharged by loosening the drain cock at the bottom of the body housing (case) by turning it counterclockwise. (After discharge, do not forget to return the drain cock to its original position by tightening it clockwise.)
With auto drain: Normally, drain discharge is performed automatically when drain accumulates, so no action is required.
However, drain can be discharged by manual operation if needed. In this case, it can be discharged by loosening the knob on the auto drain port until it points to “O” (OPEN). (Remember to return the knob to “S” (SHUT) by tightening it after discharge.)