Can KQ2 series One-touch fittings be used when the fluid is water?
What is the difference between existing KQ2 series and refreshed KQ2 series One-touch fittings?
What is the difference between KQ2H06-01AS and KQ2H06-01NS One-touch fittings? Also, what is the difference between KQ2H06-01AS and KQ2H06-01AS1 One-touch fittings?
As the KJ series has been integrated into the new KQ2 series, what is the current part number of the KJL04-M3 and KJL06-01S?
Can black be selected as the body color for new KQ2 series One-touch fittings?
Are there any SMC fittings for bulkheads with different diameters, such as when using an ø8 and ø12 tube inside and outside of a panel?
What is the meaning of the “8” and “5/16” engravings on the release button of KQ2 series One-touch fittings?
Can metal (stainless steel, copper, etc.) tubes be connected to SMC’s One-touch fittings?
What is the tightening torque of the connection thread of KQ2 series One-touch fittings?
Are there any metric size One-touch fittings with an NPT connection thread?
Are there any SMC fittings that can withstand temperatures of up to 100°C?
Can KQ2L series (union elbow) or KQ2T series (male branch tee) One-touch fittings be rotated on the body where the tube is inserted after tightening the connection thread?
Is it possible to use water or oil with KF series insert fittings?
Are the sleeves of KF series insert fittings reusable?
What is the leakage amount of KQ2 series One-touch fittings and KF series insert fittings?
What is the difference between KF series insert fittings and H/DL/L/LL series self-align fittings?
What is the difference between the “Plug: KFP” and the “Resin sleeve: KFS” of KF series insert fittings?
Are there any KK□ series S couplers with check valves on both the socket and plug sides?
Can non-air fluids be used with KK□ series S couplers?
Are there any couplers for air piping that have a One-touch fitting?
Can KK□ series S couplers be used with vacuum?
What is the sleeve lock mechanism of KK and KK130 series S couplers?
What are the different available plug side and socket side combinations for KK□ series S couplers?
Is there a stainless steel specification M-□ series miniature fitting?
What are the applicable tubing materials for M-□/MS-□ series miniature fittings?
What is the recommended tightening torque for M-□ series miniature fittings?
Can the orientation of the piping of the hose elbow/barb elbow of M-□/MS-□ series miniature fittings be changed after it has been secured?
For KQ2□-□N (electroless nickel plating), KQ2□-□G (stainless steel 303), and KG (stainless steel 303) One-touch fittings, is there a way to visually identify the products?
Is there a KQ2-G series One-touch fitting (stainless steel 303) without a stud (thread portion)?
What are the applicable fluids and the operating temperature range of KQG2 series stainless steel One-touch fittings?
Which of the following is least likely to leak: a KFG2 series stainless steel 316 insert fitting, a KQG2 series stainless steel 316 One-touch fitting, or a KQB2 series metal One-touch fitting?
What is the difference between KQG2 and KQB2 series One-touch fittings?
Are there any stainless steel plug-in reducers that can be used with a KQG2L10-04S to use a ø6 tube?
About how many millimeters should the thread diameter of the fitting and the speed controller be?
For KQ2 series One-touch fittings, is it possible to switch between metric and inch tubing?
Is silicon used on the inside of KQ2 series One-touch fittings? (The use of silicon in the device’s mechanisms is problematic for the user.)
Is it correct to believe that the IS300 series was replaced with the IS3000 series?
How can I determine the ON/OFF values of contacts “a” and “b” of an IS3000 series pneumatic pressure switch with a set pressure of 0.3 MPa?
Can the ISG series general purpose pressure switch be used with fluids other than water and air?
How do I set the pressure and hysteresis of an ISG series general purpose pressure switch?
Are there any precautions regarding the pressure adjustment range and the hysteresis adjustment range of ISG series general purpose pressure switches?
What are the possible causes of water leaking from the main body of an ISG series general purpose pressure switch installed on a water piping line, and what can be done to remedy this?