What are the possible causes of the HV LED of an IZN10/10E series ionizer turning ON (red), and what can be done to remedy this?
Why doesn’t the new IZN10E series ionizer catalog have a shielding sheet as a manifold mounting component like the old IZN10 series ionizer (IZN10-A004) had?
What are the possible causes of all the IZN10E series ionizer LEDs (PWR, NDL, and ION/HV) blinking at the same time, and what can be done to remedy this?
What are the different IZN10E series ionizer nozzle variations?
What is the material of the bender tube nozzle, which is one of the special order nozzle variations of the IZN10/10E series ionizer?
When attaching a metal pipe nozzle manufactured in-house to an IZN10/10E series ionizer with female threads for piping type (Rc1/8), what is a good material for the self-align fittings that connect the metal pipes?
Is it possible to use a special order nozzle on an IZN10E series ionizer with an energy-saving nozzle (or high flow rate nozzle)?If not, is it necessary to replace the entire ionizer with one with female threads for piping?
What are the possible causes of the NDL LED of an IZN10/10E series ionizer turning ON (orange for the IZN10 or green for the IZN10E), and what can be done to remedy this?
What are some other possible causes of the NDL LED of an IZN10/10E-11□□□-□ ionizer (female threads for piping type) turning ON (maintenance warning: orange for the IZN10 or green for the IZN10E)?The emitter is brand new and not worn out, and the problem was not resolved after cleaning the emitter and turning the power ON again.What else can I try?
The NDL LED of an IZN10/10E series ionizer turned ON (orange for the IZN10 or green for the IZN10E) indicating a maintenance warning immediately after the power was turned ON.However, as there was no emitter contamination or wear, what are the other possible causes of this, and what can be done to remedy it?
What are the possible causes of an IZS40/41/42 series ionizer ION/HV LED turning ON (red) after operation has stopped, and what can be done to remedy this?
What are the possible causes of an IZS40/41/42 series ionizer ION/HV and MAIN LED blinking red after operation has stopped, and what can be done to remedy this?
What is the wiring method for IZS40/41/42 series ionizers?
What type of AC adapter (with or without an AC cord) is available for each IZF series fan type ionizer model?
I purchased an IZF series fan type ionizer with a power cable, but I plan to purchase the AC adapter (with an AC cord) separately so that it can be used with a 100 VAC household power supply. Is there anything I need to watch out for?
Can an IZF series fan type ionizer with an AC adapter (with an AC cord) be used with a 200 VAC power supply?
Can the power cable connector of an IZF10/10R or IZF21/31 series fan type ionizer be replaced?
What are the possible causes of an IZF21/31 series ionizer NDL LED blinking red, and what can be done to remedy this?
What are the possible causes of an IZF10/10R series fan type ionizer ALM LED turning ON (red), and what can be done to remedy this? Is this the incorrect high voltage alarm?
What is the difference between the 2 types of trigger inputs (1: continuous input, 2: one-shot input) for the special order IZE110-X238 intermittent control timer, and how are they used?
Can the special order IZE110-X238 intermittent control timer be used with a solenoid valve rather than for ionizer air purge control? If so, what are the applicable solenoid valve requirements?
What is the emitter of IZ□ series ionizers?
Can external signals be used with the AC adapters provided for the various IZS/IZN/ISF series models?
What is the replacement method for IZF series fan type ionizer emitters (electrode needles)?
Is there a difference in the discharge time (static neutralization time) of IZF series fan type ionizers when the air flow is weak/strong?
How do I use the trimmer on the back surface of an IZF10(R) series ionizer?
What is the difference between old IZN10 and new IZN10E series ionizers?