What is the size selection method for VBA series booster regulators?
-
Select a booster regulator that matches the required air volume of the air to be used from the “Flow Rate Characteristics” graph in the VBA series catalog. Also, refer to the “Booster Regulator Model Selection Software” in the “Model Selection Software” section on the SMC website. The required size can be determined by inputting the necessary parameters into the selection software. Since the booster regulator generates pulsation, it is recommended that it be used in combination with a tank for booster regulators.
The “Booster Regulator Model Selection Software” can be found here.