|Boosters
-
How do I assemble a VBA series booster regulator and a VBAT series air tank?
-
Remove the plug from the bottom of the VBA series booster regulator and attach it to the OUT port on the side of the product body.
Then, put the O-ring (air tank accessory) into the groove at the bottom of the regulator.
Place the regulator on the air tank and secure it with the bolt provided.
Refer to the VBAT series operation manual for more information.
Note) The VBAT10 comes with bolts and O-rings for both the VBA1 and VBA2. It is possible to, for example, attach the smaller O-ring to the VBA10A and discard the big O-ring.
The VBAT operation manual can be found here.