|3/4/5 Port Solenoid Valves
-
How do I increase the number of stations of SJ2000/3000 series solenoid valves?
-
Confirm how to increase the number of stations for SJ series manifolds. To remove a valve connection, loosen the 2 screws securing the valve to the DIN rail. The word “FREE” will be visible when the valve lock switch of each block is slid toward the coil. In this state, remove the end block assembly and the supply/exhaust lock assembly, and increase the number of valve stations.
After increasing the number of stations, slide the valve lock switch back to its original position so that the word “FREE” is no longer visible. The upper limit of the number of valve stations differs depending on the manifold specifications (model). Refer to the catalog for details.
※Refer to the manifold exploded view in the catalog for the part numbers for additional valve stations.