|3/4/5 Port Solenoid Valves
-
Is it possible to install a non-standard pressure gauge on a VEX1 □3□ series precision regulator?
-
Yes. Non-standard pressure gauge part numbers and installation precautions are as follows.
・While it is possible to mount a G36-10-01 or G46-10-01 pressure gauge on a VEX113□/123□ series regulator, it will be larger than the width of the product body.
・It is also possible to mount a G46-10-01 pressure gauge on a VEX133 □ series regulator so long as it does not interfere with the piping.
・When mounting a pressure gauge with a non-standard pressure range on a VEX1 □3□ series regulator, keep in mind that the G36 and the G46 have a max. display pressure of either up to 0.2, up to 0.4, or up to 0.7 MPa.
The part numbers are as follows: G36(46)-2-01, G36(46)-4-01, G36(46)-7-01