Support / Contact Us » FAQ
|Electric Actuators
-
When the “RESET” signal is turned ON during operation, the operation instruction currently being executed is canceled and the actuator stops according to the “Max. speed/deceleration” set value (basic parameter).
By using this “RESET” signal, the following operations can be performed:
① Step no. 0 operation instruction → ② “RESET” signal ON (stop during operation) → ③ Step no. 2 operation instruction