|Flow Switches
-
The accuracy is described in the “Specifications” section in the PFMB7 series catalog.
The value obtained by adding the display accuracy ±3%F.S. to the sum of the temperature characteristic ±5%F.S. and the repeatability accuracy ±1%F.S. is the worst-case value of the switch output display value accuracy.
The value obtained by adding analog output accuracy ±3%F.S. to the sum of temperature characteristic ±5%F.S. and repeatability accuracy ±1%F.S. is the worst-case value of analog output accuracy.
Although this may vary depending on the product, each product should be within the range of overall accuracy.
Note) The accuracy will decline if IN side piping deviating from the recommended straight piping length or bore size is used.