Product Information »
WEB Catalog
»
Industrial Device Communication Equipment/Wireless System
»
Industrial Device Communication Equipment: IO-Link Compatible Products
Industrial Device Communication Equipment: IO-Link Compatible Products
Serial Transmission System EX260
-
For Output
∗The applicable protocols differ depending on the series.
For details, refer to the catalog of each series.
・IP67
・RJ45 communication connectors (X205)
▶IO-Link Master
Safety Instructions
3/4/5 Port Solenoid Valves/Precautions
Fieldbus System Precautions
Industrial IoT Cybersecurity
Glossary of Fieldbus Terms
Series Variations/Applicable Valve Series
Safety over Fieldbus with PROFIsafe
Green Procurement (RoHS)
IO-Link Master
Series | Enclosure | Communication protocol∗ | Applicable valve |
---|---|---|---|
EX260 | IP67 | DeviceNet™ PROFIBUS DP CC-Link EtherCAT PROFINET EtherNet/IP™ Ethernet POWERLINK IO-Link (Only available for SY, JSY, VQC communication connectors) PROFIsafe (Only available for SY, JSY, VQC communication connectors) |
SY3000,5000,7000 (Plug-in) JSY1000,3000,5000 (Plug-in) VQC1000,2000,4000,5000 SV1000,2000,3000 S0700(IP40) |
IO-Link Master EX600-GILB-X60
-
・IO-Link version V1.1
・Process data length 32-byte input/32-byte output (per port)
・IO-Link port type Class A
▶IO-Link Devices
Safety Instructions
3/4/5 Port Solenoid Valves/Precautions
Series Variations/Applicable Valve Series
Green Procurement (RoHS)
Series | Number of ports | PLC communication protocol |
---|---|---|
EX600-GILB-X60 | 4 ports | CC-Link IE Field |
Serial Transmission System EX600
-
For Input/Output
∗The applicable protocols differ depending on the series.
For details, refer to the catalog of each series.
▶IO-Link Devices
Safety Instructions
3/4/5 Port Solenoid Valves/Precautions
Fieldbus System Precautions
Industrial IoT Cybersecurity
Glossary of Fieldbus Terms
Series Variations/Applicable Valve Series
Green Procurement (RoHS)
Series | Enclosure | Communication protocol∗ | Applicable valve |
---|---|---|---|
EX600 | IP67 | PROFIBUS DP DeviceNet™ CC-Link EtherNet/IP™ EtherCAT PROFINET PROFINET (IO-Link unit compatible) MRP (PROFINET) (Made to order) Ethernet POWERLINK (Made to order) Modbus TCP (Made to order) CC-Link IE Field (Made to order) EtherNet/IP™ (IO-Link master compatible) (Made to order) |
JSY1000, 3000, 5000 (Plug-in) SY3000,5000,7000 (Plug-in) SV1000,2000,3000 VQC1000,2000,4000,5000 S0700(IP40) |
Wireless System Compact Remote EX600-W
-
・Applicable to existing wireless systems
・Compact, Lightweight
Area: Approx. 61% reduction∗ (59.8 cm2 ← 155 cm2)
Volume: Approx. 86% reduction∗ (159 cm3 ← 1,139 cm3)
Weight: Approx. 87% reduction∗ (130 g ← 965 g)
∗ For the e-CON type
(Compared with the existing remote, M8 connector/digital 8 inputs specification)
・Variations
e-CON type, Grommet type, IO-Link device compatible
▶Wireless System Base
▶IO-Link Devices
Series | Enclosure | Communication protocol | Radio wave type |
---|---|---|---|
EX600-W | e-CON type: IP20 Grommet type: IP67 IO-Link device compatible: IP67 |
SMC original protocol | Frequency Hopping Spread Spectrum (FHSS) |
Step Motor Controller JXCL1
-
・IO-Link version V1.1
・Process data length 14-byte input/22-byte output
・Transmission speed COM3 (230.4 kbps)
・Minimum cycle time 2.4 ms
・IO-Link port type Class A
・Click here for Applicable electric actuators
▶IO-Link Master
Safety Instructions
Electric Actuators/Precautions
Features
Series Variations
Simplified Selection Flow Chart
Green Procurement (RoHS)
IO-Link Master
Series | Number of axes | Compatible motor |
---|---|---|
JXCL1 | 1 axis | Step motor (Servo/24 VDC) |
Electro-Pneumatic Regulator ITV
-
・Stepless control of air pressure in proportion to electrical signals
・Sensitivity: 0.2 kPa (100 kPa specification)
・Linearity: ±1% or less (F.S.)
・Hysteresis: 0.5% or less (F.S.)
・Communication: CC-Link, DeviceNet™, PROFIBUS DP, RS-232C, IO-Link
▶IO-Link Master
Safety Instructions
F.R.L. Units/Precautions
Series Variations/Pressure Control Equipment
Green Procurement (RoHS)
IO-Link Master
Series | Port size | Set pressure (MPa) |
---|---|---|
ITV0000 | Built-in One-touch fitting φ4,φ5/32 |
0.001 to 0.1 0.001 to 0.5 0.001 to 0.9 |
ITV1000 | 1/8,1/4 | 0.005 to 0.1 0.005 to 0.5 0.005 to 0.9 |
ITV2000 | 1/4,3/8 | 0.005 to 0.1 0.005 to 0.5 0.005 to 0.9 |
ITV3000 | 1/4,3/8,1/2 | 0.005 to 0.1 0.005 to 0.5 0.005 to 0.9 |
Separate Controller Ionizer/Bar Type/Nozzle Type IZT40/41/42/43
-
・The controller and high-voltage power supply module can be mounted separately.
・Space saving: Height 37 mm x Width 30 mm (Bar type)
Thickness 16 mm x Width 53 mm x Height 32 mm (Nozzle type)
・One controller can control a maximum of 4 ionizers.
・Potential amplitude: 25 V or less
・Rapid static neutralization: Fastest time of 0.1 s
・3 types of emitter cartridges
High speed static neutralization cartridge
Energy saving static neutralization cartridge
Energy saving high-efficiency cartridge
・Static neutralization is possible even when air is not being supplied.
・IO-Link Compatible
▶IO-Link Master
Variations/Application Examples
Antistatic Equipment
Glossary
Safety Instructions
Green Procurement (RoHS)
Series | Type | Ion generation method | Offset voltage (Ion balance) |
---|---|---|---|
IZT42(-L) Bar type |
Dual AC Type | Corona discharge type | Within ±30 V |
IZT41(-L) Bar type |
AC Type | Corona discharge type | Within ±30 V |
IZT40 Bar type |
Standard Type | Corona discharge type | Within ±30 V |
IZT43(-L) Nozzle type |
AC Type | Corona discharge type | Within ±30 V |
3-Screen Display Digital Gap Checker/IO-Link Compatible ISA3-L
-
・Monitoring the placement condition of the workpiece Indicates failure/abnormality
・Double sensor providing improved preventive and predictive maintenance (IoT) based on IO-Link
Process data provides Displayed value, Outlet pressure, and Supply pressure value.
・NPN/PNP switch function
・3-screen display (Setting)
・Window comparator type
・Zero cut-off range can be changed.
▶IO-Link Master
Safety Instructions
Pressure Switches/Flow Switches/Precautions
Pressure Switch Series Variations/Application Example
Glossary of Terms/Technical Information
Green Procurement (RoHS)
IO-Link Master
Series | Rated distance range | Piping specifications: Supply side | Piping specifications: Detection side |
---|---|---|---|
ISA3-F□L | 0.01 to 0.03 mm | Rc, G 1/8 | φ4, φ6 One-touch fitting, G 1/8 |
ISA3-G□L | 0.02 to 0.15 mm | Rc, G 1/8 | φ4, φ6 One-touch fitting, G 1/8 |
ISA3-H□L | 0.05 to 0.30 mm | Rc, G 1/8 | φ4, φ6 One-touch fitting, G 1/8 |
3-Screen Display Multi-channel Digital Sensor Monitor PSE200A
-
・Up to 4 pressure sensors can be connected!
Centralized control saves installation space.
A single monitor various applications
・It is possible to change the settings while checking the measured value.
・IO-Link compatible
▶IO-Link Master
Safety Instructions
Pressure Switches/Flow Switches/Precautions
Pressure Switch Series Variations/Application Example
Glossary of Terms/Technical Information
Green Procurement (RoHS)
IO-Link Master
Series | Set pressure range | Applicable pressure sensors |
---|---|---|
PSE200A | −0.2 to 2.1 kPa 10 to −105 kPa −105 to 105 kPa −10 to 105 kPa −50 to 525 kPa −0.105 to 1.05 MPa −0.105 to 2.1 MPa −0.25 to 5.25 MPa −0.5 to 10.5 MPa |
PSE550 PSE531/PSE541/PSE561 PSE533/PSE543/PSE563/PSE573 PSE532 PSE564/PSE574 PSE530/PSE540/PSE560/PSE570 PSE575 PSE576 PSE577 |
3-Color Display Digital Flow Switch PF2MC7□(-L)
-
・Dry air, N2
・3-color/3-screen display
・A wide range of flow measurement is possible with 1 product.
Flow ratio 100:1, Smallest settable increment: 1 L/min
・Grease-free
・IO-Link compatible
▶IO-Link Master
Safety Instructions
Pressure Switches/Flow Switches/Precautions
Flow Switch Series Variations
Green Procurement (RoHS)
IO-Link Master
Series | Rated flow range (L/min) |
---|---|
PF2MC | 5 to 500 10 to 1000 20 to 2000 |
3-Color Display Digital Flow Switch PFMC7□(-L)
-
・Dry air, N2
・3-color/2-screen display
・Expanded flow range: A wide range of flow measurement is possible with 1 product.
・Compact, Space saving
・IO-Link compatible
▶IO-Link Master
Safety Instructions
Pressure Switches/Flow Switches/Precautions
Flow Switch Series Variations
Green Procurement (RoHS)
IO-Link Master
Series | Rated flow range (L/min) |
---|---|
PFMC | 5 to 500 10 to 1000 20 to 2000 |
2-Color Display Digital Flow Switch PF2M7(-L)
-
・Dry air, N2, Ar, CO2
・A wide range of flow measurement is possible with 1 product.
Flow ratio: 100:1, Smallest settable increment: 0.01 L/min
・Improved resistance to moisture and foreign matter
・Compact, Lightweight
Weight: 27.3% lighter (55 g → 40 g)
・Low current consumption: 35 mA or less
・Grease-free
・IO-Link compatible
▶IO-Link Master
Safety Instructions
Pressure Switches/Flow Switches/Precautions
Flow Switch Series Variations
Green Procurement (RoHS)
IO-Link Master
Series | Rated flow range (L/min) |
---|---|
PF2M7 | 0.01 to 1 (0.01 to 0.5) 0.02 to 2 (0.02 to 1) 0.05 to 5 (0.05 to 2.5) 0.1 to 10 (0.1 to 5) 0.3 to 25 (0.3 to 12.5) 0.5 to 50 (0.5 to 25) 1 to 100 (1 to 50) 2 to 200 (2 to 100) ( ): For CO2 |
3-Color Display Digital Flow Switch for Water PF3W-Z/L
-
・Applicable fluid: Water, Ethylene glycol aqueous solution
・Lightweight: Max. 53% reduction (40 L/min, With temperature sensor)
・IO-Link compatible
・3-color/2-screen display
・Compatible with the temperature sensor & flow adjustment valve
・Fluid temperature: 0 to 90℃
▶IO-Link Master
Safety Instructions
Pressure Switches/Flow Switches/Precautions
Flow Switch Series Variations
Green Procurement (RoHS)
IO-Link Master
Series | Rated flow range (L/min) |
---|---|
PF3W-Z | 0.5 to 4 2 to 16 5 to 40 10 to 100 |
PF3W-L (IO-Link compatible) |
0.5 to 4 2 to 16 5 to 40 10 to 100 50 to 250 |
Digital Flow Switch Manifold for Water PF3WB/C/S/R
-
・Applicable fluid: Water, Ethylene glycol aqueous solution
・Space saving
Footprint Max. 85% reduction
Weight Max. 65% reduction
・Needs no piping: Work-hour for installation reduced by up to 45%
・IO-Link compatible
・3-color/2-screen display
・Fluid temperature: 0 to 90℃
▶IO-Link Master
Safety Instructions
Pressure Switches/Flow Switches/Precautions
Flow Switch Series Variations
Green Procurement (RoHS)
IO-Link Master
Series | Rated flow range (L/min) |
---|---|
PF3WB Integrated type (Basic type) |
0.5 to 4 2 to 16 5 to 40 |
PF3WC Integrated type (Straight type) |
0.5 to 4 2 to 16 5 to 40 |
PF3WS Remote type (Supply type) |
0.5 to 4 2 to 16 5 to 40 |
PF3WR Remote type (Return type) |
0.5 to 4 2 to 16 5 to 40 |
3-Color Display Digital Flow Switch for Large Flow PF3A□H(-L)
-
・Applicable fluid: Air, N2
・Flow range: Max. 12000 L/min
・Flow ratio 100:1
A wide range of flow measurement is possible with 1 product.
・Improved drainage and resistance to foreign matter
・Pressure loss: 75% reduction (20 kPa → 5 kPa)
・Through bore construction
・IO-Link compatible
・Can be connected to the air combination (Modular type)
・A 4-screen display digital flow switch with pressure/temperature sensor
(modular type) is available.
Simultaneous measurement of the (accumulated) flow rate, pressure, and temperature is possible.
▶IO-Link Master
Safety Instructions
Pressure Switches/Flow Switches/Precautions
Green Procurement (RoHS)
IO-Link Master
Series | Rated flow range (L/min) |
---|---|
PF3A7□H | 10 to 1000 20 to 2000 30 to 3000 60 to 6000 120 to 12000 |
Digital Flow Switch for Water PF3W7□-X445
-
・IO-Link version V1.1
・Process data length 6-byte input
・Transmission speed COM2 (38.4 kbps)
・Minimum cycle time 3.5 ms
・IO-Link port type Class A
▶IO-Link Master
Safety Instructions
Pressure Switches/Flow Switches/Precautions
Flow Switch Series Variations
Green Procurement (RoHS)
IO-Link Master
Series | Applicable fluid | Rated flow range |
---|---|---|
PF3W704-X445 | Water | 0.5 to 4 L/min |
PF3W720-X445 | Water | 2 to 16 L/min |
PF3W740-X445 | Water | 5 to 40 L/min |
Actuator Position Sensor D-MP025/050/100/200
-
・IO-Link version V1.1
・Process data length 2-byte input
・Transmission speed COM3 (230.4 kbps)
・Minimum cycle time 1.0 ms
・IO-Link port type Class A
▶IO-Link Master
Safety Instructions
Actuators/Precautions
Auto Switches/Precautions
Green Procurement (RoHS)
IO-Link Master
Series | Measurement range |
---|---|
D-MP025 | 25mm |
D-MP050 | 50mm |
D-MP100 | 100mm |
D-MP200 | 200mm |